Loading...
042519 HEX BHS BLDG 100 PLN51159 CUP SPR Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 1 of 16 BEFORE THE HEARING EXAMINER FOR THE CITY OF BAINBRIDGE ISLAND In the Matter of the Application of ) No. PLN 51159 SPR/CUP ) Ilva Wilson, on behalf of Bainbridge ) Island School District 303 ) ) For Approval of a Site Plan and Design ) FINDINGS, CONCLUSIONS, Review and Major Conditional Use Permit ) AND DECISION (Corrected May 10, 2018) SUMMARY OF DECISION The request for a site plan/design review and a major conditional use permit to demolish an existing 41,509 square foot classroom and a 2,803 square foot music building on the Bainbridge High School campus and to construct a 35,500 square foot class room building located at 9330 NE High School Road is APPROVED. Conditions are necessary to mitigate specific impacts of the proposed development. SUMMARY OF RECORD Hearing: The Hearing Examiner held an open record hearing on the request on April 25, 2019. Testimony: The following individuals testified under oath at the open record hearing: David Greetham, Senior City Planner Joann Wilcox, Applicant Architect Exhibits: The following exhibits were admitted into the record: 1. Staff Report, April 18, 2019 2. Master Land Use Application, dated November 21, 2018 3. Environmental (SEPA) Checklist, with staff notes, dated November 16, 2018 4. Notice of Complete Application, dated December 19, 2018 5. Notice of Application/SEPA Comment Period/Hearing, dated January 11, 2019 6. Mailing list, dated January 11, 2019; Legal Invoice, Bainbridge Island Review, Legal #: BIR84056, dated January 11, 2019; Affidavit of Publication, Bainbridge Island Review, dated January 11, 2019; classified proof, published January 11, 2019; Certificate of Posting, dated January 17, 2019 7. Notice of Mitigated Determination of Nonsignificance (MDNS), issued March 22, 2019 Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 2 of 16 8. Planning Commission Recorded Motion, dated April 22, 2019 9. Four site plan drawings, undated 10. Applicant PowerPoint (26 slides), dated April 25, 2019 11. City PowerPoint (five slides), dated April 25, 2019 12. Memorandum from Peter Corelis, P.E., to David Greetham, dated April 24, 2019 13. Design Review Board minutes, dated December 17, 2018 14. Layout Plan (Sheet L-100), dated November 21, 2018 The Hearing Examiner enters the following findings and conclusions based upon the testimony at the open record hearing and admitted exhibits: FINDINGS Application and Notice 1. Ilva Wilson, on behalf of Bainbridge Island School District 303 (Applicant), requests a site plan and design review (SP&DR) and a major conditional use permit (CUP) to demolish an existing 41,509 square foot classroom and assembly building (Building 100) and a 2,803 square foot music building on the Bainbridge High School (BHS) campus and to construct a 35,500 square foot class room building with a building height of 30 feet. The school property is located at 9330 NE High School Road.1 Exhibit 1, Staff Report, page 1; Exhibit 2; Exhibit 9; Exhibit 14. 2. The City of Bainbridge Island (City) determined the application was complete on December 19, 2018. The City issued a Notice of Application/SEPA Comment Period/Hearing on January 11, 2019, by publishing notice in the Bainbridge Island Review, providing notice to those on a mailing list that included the Applicant and property owners within 500 feet of the subject property, and posting two notices on-site, with a comment deadline of January 25, 2019. The City received no public comments in response to the notice. Exhibit 1, Staff Report, pages 5 and 7; Exhibit 4; Exhibit 5. 3. The Bainbridge Fire Department provided comments and proposed conditions (Nos. 17 through 22) as part of the pre-application process. The City Building Official and Public Works-Engineering also provided comments and proposed conditions (Nos. 11 through 16 and 23 through 26). Exhibit 1, Staff Report, page 7. State Environmental Policy Act 4. The City acted as lead agency and analyzed the environmental impact of the proposal, as required by the State Environmental Policy Act (SEPA), Chapter 43.21C RCW. The City consolidated the application and SEPA comment periods under the Optional DNS process provided for by the Washington Administrative Code (WAC) 197-11-355, with a 1 The property is identified by tax parcel number 222502-4-003-2008. Exhibit 1, Staff Report, page 1. A legal description is provided in the Environmental Checklist. Exhibit 3. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 3 of 16 comment deadline of January 25, 2019. Notice materials stated that the City expected to issue a Determination of Nonsignificance (DNS) for the proposal. The City reviewed the Applicant’s Environmental Checklist and other information on file and determined that, with mitigation, the proposal would not have a probable significant adverse impact on the environment. The City’s Responsible SEPA Official issued a Mitigated Determination of Nonsignificance (MDNS) on March 22, 2019, with an appeal deadline of April 5, 2019. The MDNS contains three conditions to address the limits of clearing and grading in the field, dust management, and managing and disposing of dangerous wastes from demolition. The MDNS was not appealed. No critical areas were identified within the proposed site work area. Exhibit 1, Staff Report, pages 1, 3, and 7; Exhibit 5; Exhibit 7. Comprehensive Plan and Zoning 5. The City’s Comprehensive Plan designates the property as Semi-Urban-2.9. The City identified Comprehensive Plan goals and policies that are relevant to the proposal: Capitol Facilities Element policy prioritizes projects, including replacing worn-out or obsolete facilities. The Comprehensive Plan adopted the Bainbridge Island School District 2014-2020 Capital Facilities Plan (October 2014) by reference. The District Plan identifies the “BHS 100 Building” as not complying with current building codes. Environmental Element policy employs conservation design methods, such as low-impact development techniques. Utilities Element includes a goal to manage stormwater runoff and policies to avoid both on-site and off-site improvements to avoid adverse water quality and quantity impacts, minimize disruption or degradation of natural drainage systems, and encourage new development to integrate environmentally responsible and innovate energy system.2 Exhibit 1, Staff Report, pages 5 and 6. 6. The property is located in the City’s Residential zone (R-2.9). The purpose of the R-2.9 zone is to provide for vital residential neighborhoods in a suburban residential area. Bainbridge Island Municipal Code (BIMC) 18.06.020.D. A CUP is a mechanism by which the City may require specific conditions on development, or on the use of land, to ensure that designated uses or activities are compatible with other uses in the same zone and in the vicinity of the property. If imposition of conditions will not make a specific proposal compatible, the proposal must be denied. BIMC 2.16.110.A. Educational facilities are allowed in the R-2.9 zone with CUP approval. BIMC Table 18.09.020 Use Table. Exhibit 1, Staff Report pages 3 and 5. 7. The allowable lot coverage in the R-2.9 zone is 25 percent. Existing lot coverage is estimated at approximately 12 percent. Following demolition of the 44,300 square foot 2 City staff identified Comprehensive Plan Capitol Facilities Element Policy CF-1.5; Environmental Element Polity EN-4.1; and Utilities Element Goal U-13 and Policies U.12.3, 13.2, 13.5, and 14.8. Exhibit 1, Staff Report, pages 5 and 6. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 4 of 16 existing building, the redeveloped building would cover approximately 35,500 square feet. The proposed building would exceed the required 25-foot minimum front and rear yard and 15-foot minimum rear and side yard setbacks. The 25-foot maximum building height can be increased by five feet if CUP conditions are met. BIMC Table 18.12.020-2. City staff recommended approval of this height bonus. Exhibit 1, Staff Report, page 8. Existing Site 8. BHS is located on a single, 73.75-acre, multi-purpose parcel. Building 100 (to be demolished) and the music building are located in the interior portion of the school campus, within a cluster of four large buildings, with parking areas to the west. The BHS campus fronts on NE High School Road, a secondary arterial. The Environmental Checklist describes the parcel as hilly and generally sloping 30 percent from north to southwest, with the highest elevation at approximately 260 feet, in the north and northeastern portion of the 2.5-acre project work site, and the lowest elevation point at approximately 220 feet, in the southwestern corner of the parcel. The proposed project would not increase student capacity or increase average daily traffic trips, nor would noise standards be exceeded. The project is part of a phased plan to replace deficient school district buildings. Exhibit 1, Staff Report, page 1, 8, 14, and 15; Exhibit 3. Site Plan and Design Review 9. The City Design Review Board (DRB) reviewed the site plan and design at meetings on June 18, August 20, November 5, and December 4, 2018. The DRB determined that the proposal would comply with the requirements of the City’s commercial/mixed use design guidelines. BIMC 18.18.030.C. The DRB recommended approval, with concerns about the design and location of the final memorial and a need for further articulation of the eastern wall, in addition to landscaping. The City Planning Commission recommended approval of the project by unanimous vote on April 11, 2019. City staff also reviewed the application and determined that, as conditioned, the proposal would comply with the City’s site plan and design review criteria. Exhibit 1, Staff Report, pages 7, 10, 11, and 14; Exhibit 8; Exhibit 13. Institutions in Residential Zones and Design Review 10. The proposed use is an education facility in a residential zone, such that decision criteria in BIMC 2.16.110.G apply. City staff determined that a traffic study is not required since there would be no increase in traffic, that the current perimeter buffer located west of the work site meets minimum standards, that the replacement building would be compatible with the bulk and height of other surrounding campus buildings, and that lot coverage would not exceed 50 percent of the allowable lot coverage. Exhibit 1, Staff Report, pages 13 through 14; Exhibit 14. Parking and Traffic 11. The City Engineer determined that the current bicycle, vehicular and pedestrian circulation systems for the BHS campus would remain unchanged, with the exception of Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 5 of 16 new walkways around the replacement building. No new traffic trips are planned, and no new impacts to existing streets and pedestrian ways are anticipated. The proposed use is in accord with the Island-Wide Transportation Plan. Exhibit 1, Staff Report, pages 10, 11, and 13. Stormwater 12. The Applicant would address storm water by tying into an existing drainage system with planned upgrades for water-quality treatment. The City will conduct detailed stormwater review at the building permit stage. The City Engineer reviewed the application and determined that the proposed use conforms to the drainage regulations in Chapters 15.20 and 15.21 BIMC and would not cause an undue burden on the drainage basin or unreasonably interfere with the use and enjoyment of properties downstream. In addition, the City Engineer determined that the site plan and design would meet specific design requirements by tying into an existing drainage system and by complying with the 2014 Ecology Stormwater Manual minimum requirements for new and replaced hard surfaces and for land disturbance areas. Two stormwater biofiltration facilities are proposed. Prior to construction, the Applicant would submit a temporary erosion and sedimentation control plan to the City for approval. Exhibit 1, Staff Report, pages 3, 8, 10, and 16; Exhibit 14. Utilities 13. The proposed use would be served by adequate public facilities. The school campus is served by City sewer and water. The Bainbridge Island Police Department and Bainbridge Island Fire District provides police and fire service. Exhibit 1, Staff Report, pages 3, 10, 11, and 12; Testimony of Mr. Greetham. Landscaping 14. City code requires 40 tree units per acre, or at least the same number of tree units after proposed development. The Applicant would remove six non-landmark trees and add 12 new trees. The Applicant would provide a tree unit survey prior to final building inspection. New landscape planting-beds would be provided around the building, and native vegetation would be installed in the two planned stormwater biofiltration facilities. Existing perimeter landscaping would remain in place. The existing perimeter buffer located west of the work site meets minimum standards, with a forested strip ranging from approximately 25 to 100 feet in width. Outdoor lighting would meet the City’s code requirements. BIMC 18.15.040. Exhibit 1, Staff Report, page 8, 9, 10, 14, and 17; Exhibit 14. Testimony 15. Senior City Planner David Greetham testified generally about the application review process, explaining that the City reviewed the application for consistency with the major conditional use permit criteria and site plan/design review criteria. He testified that no Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 6 of 16 traffic study was required, that a five-foot height bonus was appropriate because the height would be below the existing building, that the City received no comments from the public, and that the Planning Commission recommended approval of the proposal. Testimony of Mr. Greetham. 16. Joann Wilcox, architect for the Applicant, with 26 years of experience, testified generally in support of the application and answered questions of the Hearing Examiner. She testified that the proposed building would meet sustainability standards provided by the Superintendent of Public Instruction, which is equivalent to LEED certification. She requested that proposed Condition 4 be amended to reference the Applicant’s PowerPoint (Exhibit 10, page 12), as well as Exhibit 14, the Layout Plan, dated November 21, 2018. Testimony of Ms. Wilcox. 17. City Development Engineer Peter Corelis, P.E., prepared a Memorandum, dated April 24, 2019, with proposed changes to the staff report, including deleting Conditions No. 7 and 25, and adding a Public Works Condition that would read: “Any increase of water supply fixture units or placement of fixtures shall require analysis at the building permit stage to ensure adequate domestic water service pressure is met.” Exhibit 12. Staff Recommendation 18. City staff determined that the proposal would be consistent with the City’s Comprehensive Plan, municipal code, and development standards. City staff recommended approval of the major CUP and site plan/design review, with conditions as modified during the hearing. Exhibit 1, Staff Report, pages 15 through 18; Exhibit 12. CONCLUSIONS Jurisdiction The Hearing Examiner is granted jurisdiction to hear and approve, approve with conditions, or deny applications for conditional use permits under BMIC 2.14.030 and BMIC 2.16.110.D. If requested by the Applicant, a site plan and design review application that is part of a proposal requiring multiple land use permits may be combined in a consolidated project review. Related applications requiring a public hearing must be considered at one public hearing in accordance with BIMC 2.16.170. The applications have been consolidated for review before the Hearing Examiner. BIMC 2.16.170. Decisions are needed for the applications for site plan and design review and the CUP. The City Council has established criteria for review of each of these applications, which the Hearing Examiner must follow when deciding whether to approve a specific application. Site Plan and Design Review The following criteria apply to recommendations or decisions on site plan and design review applications: Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 7 of 16 F. Design Criteria 1. The site plan and design is in conformance with applicable code provisions and development standards of the applicable zoning district, unless a standard has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.S; 2. The locations of the buildings and structures, open spaces, landscaping, pedestrian, bicycle and vehicular circulation systems are adequate, safe, efficient and in conformance with the Island- Wide Transportation Plan; 3. The Kitsap County health district has determined that the site plan and design meets the following decision criteria: a. The proposal conforms to current standards regarding domestic water supply and sewage disposal; or if the proposal is not to be served by public sewers, then the lot has sufficient area and soil, topographic and drainage characteristics to permit an on-site sewage disposal system. b. If the health district recommends approval of the application with respect to those items in subsection E.3.a of this section, the health district shall so advise the director. c. If the health district recommends disapproval of the application, it shall provide a written explanation to the director; 4. The city engineer has determined that the site plan and design meets the following decision criteria: a. The site plan and design conforms to regulations concerning drainage in Chapters 15.20 and 15.21 BIMC; and b. The site plan and design will not cause an undue burden on the drainage basin or water quality and will not unreasonably interfere with the use and enjoyment of properties downstream; and c. The streets and pedestrian ways as proposed align with and are otherwise coordinated with streets serving adjacent properties; and d. The streets and pedestrian ways as proposed are adequate to accommodate anticipated traffic; and e. If the site will rely on public water or sewer services, there is capacity in the water or sewer system (as applicable) to serve the site, and the applicable service(s) can be made available at the site; and f. The site plan and design conforms to the “City of Bainbridge Island Design and Construction Standards,” unless the city engineer has approved a variation to the road standards in that document based on his or her determination that the variation meets the purposes of BIMC Title 18; Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 8 of 16 5. The site plan and design is consistent with all applicable design guidelines in BIMC Title 18, unless strict adherence to a guideline has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.S; 6. No harmful or unhealthful conditions are likely to result from the proposed site plan; 7. The site plan and design is in conformance with the comprehensive plan and other applicable adopted community plans; 8. Any property subject to site plan and design review that contains a critical area or buffer, as defined in Chapter 16.20 BIMC, conforms to all requirements of that chapter; 9. Any property subject to site plan and design review that is within shoreline jurisdiction, as defined in Chapter 16.12 BIMC, conforms to all requirements of that chapter; 10. If the applicant is providing privately owned open space and is requesting credit against dedications for park and recreation facilities required by BIMC 17.20.020.C, the requirements of BIMC 17.20.020.D have been met; 11. The site plan and design has been prepared consistent with the purpose of the site design review process and open space goals. G. Action of Director. The director may approve, approve with conditions, or disapprove the application for site plan and design review. Conditions may be imposed to enable the proposal to meet the standards of the decision criteria. BIMC 2.16.040. Conditional Use Permit A major conditional use permit is a mechanism by which the city may require specific conditions on development or the use of land to ensure that designated uses or activities are compatible with other uses in the same zone and in the vicinity of the subject property. If imposition of conditions will not make a specific proposal compatible the proposal shall be denied. BIMC 2.16.110.A. A conditional use may be approved or approved with conditions if: a. The conditional use is harmonious and compatible in design, character and appearance with the intended character and quality of development in the vicinity of the subject property and with the physical characteristics of the subject property; provided, that in the case of a housing design demonstration project any differences in design, character or appearance that are in furtherance of the purpose and decision criteria of BIMC Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 9 of 16 2.16.020.Q shall not result in denial of a conditional use permit for the project; and b. The conditional use will be served by adequate public facilities including roads, water, fire protection, sewage disposal facilities and storm drainage facilities; and c. The conditional use will not be materially detrimental to uses or property in the vicinity of the subject property; and d. The conditional use is in accord with the comprehensive plan and other applicable adopted community plans, including the Island-Wide Transportation Plan; and e. The conditional use complies with all other provisions of the BIMC, unless a provision has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.Q; and f. All necessary measures have been taken to eliminate or reduce to the greatest extent possible the impacts that the proposed use may have on the immediate vicinity of the subject property; and g. Noise levels shall be in compliance with BIMC 16.16.020 and 16.16.040.A; and h. The vehicular, pedestrian, and bicycle circulation meets all applicable city standards, unless the city engineer has modified the requirements of BIMC 18.15.020.B.4 and B.5, allows alternate driveway and parking area surfaces, and confirmed that those surfaces meet city requirements for handling surface water and pollutants in accordance with Chapters 15.20 and 15.21 BIMC; and i. The city engineer has determined that the conditional use meets the following decision criteria: i. The conditional use conforms to regulations concerning drainage in Chapters 15.20 and 15.21 BIMC; and ii. The conditional use will not cause an undue burden on the drainage basin or water quality and will not unreasonably interfere with the use and enjoyment of properties downstream; and Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 10 of 16 iii. The streets and pedestrian ways as proposed align with and are otherwise coordinated with streets serving adjacent properties; and iv. The streets and pedestrian ways as proposed are adequate to accommodate anticipated traffic; and v. If the conditional use will rely on public water or sewer services, there is capacity in the water or sewer system (as applicable) to serve the conditional use, and the applicable service(s) can be made available at the site; and vi. The conditional use conforms to the “City of Bainbridge Island Engineering Design and Development Standards Manual,” unless the city engineer has approved a variation to the road standards in that document based on his or her determination that the variation meets the purposes of BIMC Title 17. j. If a major conditional use is processed as a housing design demonstration project pursuant to BIMC 2.16.020.Q, the above criteria will be considered in conjunction with the purpose, goals, policies, and decision criteria of BIMC 2.16.020.Q. BIMC 2.16.110.F.1. “If no reasonable conditions can be imposed that ensure the application meets the decision criteria of this chapter, then the application shall be denied.” BIMC 2.16.110.F.2. The City has determined that the proposal is categorized as an educational facility under BIMC Table 18.09.020, and must also meet the decision criteria for institutions in residential zones: 1. All sites must front on roads classified as residential suburban, collector, or arterial on the Bainbridge Island functional road classification map. 2. If the traffic study shows an impact on the level of service, those impacts have been mitigated as required by the city engineer. 3. If the application is located outside of Winslow study area, the project shall provide vegetated perimeter buffers in compliance with BIMC 18.15.010. 4. The proposal meets the requirements of the commercial/mixed use design guidelines in BIMC 18.18.030.C. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 11 of 16 5. The scale of proposed construction including bulk and height and architectural design features is compatible with the immediately surrounding area. 6. If the facility will have attendees and employees numbering fewer than 50 or an assembly seating area of less than 50, the director may waive any or all the above requirements in this subsection E, but may not waive those required elsewhere in the BIMC. 7. Lot coverage does not exceed 50 percent of the allowable lot coverage in the zone in which the institution is located, except that public schools and governmental facilities, as defined in BIMC Title 18, that are located in the R-0.4 zoning district shall be allowed 150 percent of the lot coverage established in the R-0.4 zoning district, and such public schools and governmental facilities located in other zoning districts shall be allowed 100 percent of the lot coverage established in the underlying zoning district in which the facility is located, unless, regardless of which zoning district such a facility is located, conditions are required to limit the lot coverage to mitigate impacts of the use. BIMC 2.16.110.G. The criteria for review adopted by the City Council are designed to implement the requirement of Chapter 36.70B RCW to enact the Growth Management Act. In particular, RCW 36.70B.040 mandates that local jurisdictions review proposed development to ensure consistency with City development regulations, considering the type of land use, the level of development, infrastructure, and the characteristics of development. RCW 36.70B.040. Conclusions Based on Findings Site Plan and Design Review 1. With conditions, the site plan and design review application meets the criteria for approval. The City provided reasonable notice for public comment and testimony. The site plan and design is in conformance with applicable code provisions and development standards of the R-2.9 zoning district. The proposed building would replace two existing buildings and would continue to be in conformance with the Island-Wide Transportation Plan. The City would continue to provide water and sewer service to the site. In addition, the City Engineer determined that the site plan and design would meet specific requirements by tying into an existing drainage system and not cause an undue burden on the drainage basin or water quality or unreasonably interfere with the use and enjoyment of properties downstream. The project would conform to the City’s Design and Construction standards. The City’s Design Review Board reviewed the design guidelines in Title 18 BIMC and recommended approval with conditions and additional review prior to issuance of a Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 12 of 16 building permit. No harmful or unhealthful conditions are likely to result from the proposed site plan. The City reviewed the project, the Applicant’s Environmental Checklist, and other information on file. No critical areas were identified. The City issued an MDNS, with conditions. The MDNS was not appealed. The site plan and design is in conformance with the comprehensive plan and other applicable adopted community plans. Conditions are necessary, including those to ensure that the Applicant complies with the landscape plan and submits a tree unit survey prior to final building inspection. Findings 1-10, 18. Conditional Use Permit 2. With conditions, the proposal would meet the major CUP criteria of BIMC 2.16.110.F.1 and .G. The City provided reasonable notice for public comment and testimony. The City reviewed the project, the Applicant’s Environmental Checklist, and other information on file. No critical areas were identified. The City issued an MDNS, with conditions. The MDNS was not appealed. The proposed use would not result in significant changes to the design, character, or appearance of the area because the BHS is already located on the property. The BHS campus would continue to be harmonious and compatible with development in the vicinity. The proposed building replacement would take place within the interior of the BHS campus. Lot coverage would continue to be less than 25 percent with the project. The existing perimeter buffer located west of the work site meets minimum standards, with a forested strip ranging from approximately 25 to 100 feet in width. The City Engineer determined that the proposed use would be adequately served by public facilities, including roads and water, and that fire protection, sewage disposal facilities and storm drainage facilities. Storm water treatment requirements would be addressed at building permit review. The proposed use would be consistent with the Comprehensive Plan, which allows educational facilities within residential zones with a CUP. The Applicant would comply with the noise levels established by the City. The City Engineer determined that the proposed use would meet the requirement for vehicular circulation on-site. The proposed use complies with all other provisions of the BIMC. With conditions, all necessary measures have been taken to eliminate, or reduce to the greatest extent possible, the impacts that the proposed use may have on the immediate vicinity of the property. Because the proposal meets the CUP criteria, a building height bonus of five feet is also approved. Conditions are necessary, including those to ensure that the project complies with the SEPA conditions and that the Applicant obtains all appropriate City permits; complies with the Fire Code and International Building Code; constructs the project in substantial conformance with the landscape plan; and demonstrates compliance with storm water requirements with the submittal of a building permit. Findings 1-8, 11-18. 3. With conditions, the proposal would be meet the additional major CUP criteria of BIMC 2.16.110.G for institutions in residential zones. The property fronts NE High School Road, a secondary arterial road. No impacts to traffic were identified that would Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 13 of 16 reduce the level of service. The Design Review Board reviewed the proposal and recommended approval with conditions, including compliance with the City’s commercial/mixed use design guidelines. The existing buildings are compatible with the surrounding residential uses. Lot coverage would meet the City code. The existing perimeter buffer located west of the work site meets minimum standards, with a forested strip ranging from approximately 25 to 100 feet in width. Conditions are necessary to ensure the proposed development is consistent with City code requirements and does not have adverse impacts on surrounding properties. Findings 1-10, 18. DECISION Based on the preceding findings and conclusions, the request for approval of a site plan/design review permit and a major conditional use permit to demolish an existing 41,509 square foot classroom and a 2,803 square foot music building on the Bainbridge High School campus and to construct a 35,500 square foot class room building with a building height of 30 feet, located at 9330 NE High School Road, is APPROVED, with the following conditions:3 SEPA Conditions: 1. The limits of clearing and grading shall be clearly marked in the field and inspected by the Department of Planning and Community Development staff prior to start of any clearing, grading, or other site work. 2. Dust shall be managed in compliance with WAC 173-400 and Puget Sound Clean Air Agency –Regulation I, 9.15 (PSCCA Reg). The project proponent or contractor shall prepare and implement a “Dust Control Plan” in conformance with Department of Ecology Publication 96-433. Prior to any site activity, the “Dust Control Plan” shall be submitted to the City and it shall be actively managed for the duration of the project. Unlawful emissions (see below) shall be corrected immediately and/or dust generating operations ceased until additional or alternate BMPs can be implemented to maintain emissions below allowable levels. "Fugitive dust" means a particulate (especially soil/dirt) emission made airborne by forces of nature, man's activity, or both, that leaves the subject site. Unlawful emissions shall generally be defined as emissions leaving the subject property that are visible to an untrained observer. Where continuous monitoring equipment is used particulate matter concentrations shall be monitored for 10μm particle (PM10) size. The 24-hr average PM10 emissions shall not exceed a concentration equivalent to the EPA Air Quality Index (AQI) of 50 (54μg/m³) and any instantaneous PM10 emissions shall not exceed a concentration equivalent to an AQI of 100 (154μg/m³). 3 Conditions include both legal requirements applicable to all developments and requirements to mitigate the specific impacts of this development. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 14 of 16 3. Dangerous wastes from demolition activities shall be properly managed and disposed of in accordance with state and federal requirements. These include but are not limited to: a) the “Mercury-Containing Lights – Proper Disposal” law, Chapter 70.275 RCW; b) evaluation for asbestos, and if identified, removal and disposal in accordance with Puget Sound Clean Air Agency Regulations; and c) evaluation for lead concentrations to determine if they exceed dangerous thresholds. If lead-bearing components designate as hazardous waste, all related debris must be managed appropriately and cannot be disposed of as municipal trash. Project Conditions: 4. Except for modifications reflecting compliance with these conditions of approval, the project shall be in substantial conformance with the site and landscape plans dated November 21, 2018 (Exhibit 14 and Exhibit 10, page 12). 5. Prior to construction activity, the Applicant shall obtain the appropriate permits from the City of Bainbridge Island, including but not limited to grading, demolition, and building permits. 6. All work shall adhere to the City’s seasonal work limitations between October 1 and April 30 of any year. During this period, no soils shall remain exposed and unworked for more than two days. From May 1 to September 30, no soils shall remain exposed and unworked for more than seven days. 7. [deleted] 8. Construction activities shall comply with the noise limitations at BIMC 16.16.020 (maximum environmental noise levels) and BIMC 16.16.025 (limitations in residential zones). 9. Outdoor lighting shall be installed in accordance with the outdoor lighting standards at BIMC 18.15.040. 10. A tree unit survey shall be provided prior to final building inspection to ensure that the designated project area includes at least the same number of tree units after the proposed redevelopment as it had before the redevelopment. Calculation of tree units shall be based on BIMC Table 18.15.010-5 for preserved trees, and BIMC 18.15.010.G.5.c for newly planted trees. 11 The project shall comply with the City of Bainbridge Island (COBI) construction codes as adopted by Chapter 15.04 BIMC. The Applicant shall consult with the Building Official to coordinate with design professionals as necessary for this project to ensure compliance with applicable standards. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 15 of 16 12. The project shall comply with the requirements of the Department of Labor and Industries (L&I) for Electrical permits. COBI does not issue electrical permits but does monitor and coordinate electrical approvals with L&I. 13. The project shall comply with the provisions of the International Building Code for fire separation, fire protection, access, and the application of fire suppression systems as required by State Building Codes and the City of Bainbridge Island Fire District. The Applicant shall consult with the Fire District and coordinate with design professionals as necessary for this project to ensure compliance with applicable standards. 14. The project shall comply with the provisions of the International Building Code, Chapter 11 and ANSI 117.1 2009 for the application of accessibility and accessible features, including but not limited to parking, path of travel, entry and egress components and interior features and restrooms. 15. Application for all demolition is required to be submitted to the Puget Sound Clean Air Agency prior to issuance of a COBI building demolition permit. 16. All demolition shall be documented with a minimum 8.5 x 11 drawing showing the location of structures to be demolished including footprint and setbacks from all property lines and utilities as currently installed. 17. The proposed project shall comply with all applicable provisions of the adopted Fire Code. 18. The proposed Fire Lane shall be a minimum 20’ width. Bollard placement along the lane shall be verified with the Fire Department prior to installation. 19. Shop classroom uses such as spray painting, woodworking operations (dust collection), hazardous materials handling, etc., shall be subject to applicable Fire Code standards. 20. The fire alarm system shall be networked to the 200 building and annunciate there. 21. The sprinkler design PSI available shall be verified with the Fire Department prior to installation. 22. The raku kiln shall be setback a minimum of 25’ from any structure. 23. With the submittal of the building permit, the Applicant shall demonstrate how storm water will be handled in conformance with current Chapter 15.20 BIMC regulations. Findings, Conclusions, and Decision City of Bainbridge Island Hearing Examiner Bainbridge High School Building 100 Replacement SPR/CUP No. PLN 51159 SPR/CUP Page 16 of 16 24. Low-impact development methods for stormwater management shall be incorporated into the site to the maximum extent feasible. 25. [deleted] 26. Prior to building permit issuance, a binding commitment letter for water and sewer availability is required. 27. The land use permits shall automatically expire and become void if the Applicant fails to apply for a building permit or other necessary development permit within three years of the effective date of the permit unless the Applicant has received an extension for the permit. 28. Any increase of water supply fixture units or placement of fixtures in the building resulting in an increase in water pressure demand or flow shall require analysis at the building permit stage to ensure adequate domestic water service pressure is met. Originally issued May 7, 2019. Re-issued with corrections, this 10th day of May 2019. THEODORE PAUL HUNTER Hearing Examiner Sound Law Center EXHIBIT LIST Name App: Bainbridge High School Building 100 Replacement PLN# 51159 CUP SPR Staff Contact: David Greetham, Public Hearing: 4/25/19 Senior Planner City Hall – Council Chambers City of Bainbridge Island Hearing Examiner NO. DOCUMENT DESCRIPTION DATE 1 Staff Report 4/18/19 2 Application 11/21/18 3 Environmental (SEPA) Checklist 11/16/18 4 Notice of Complete Application 12/19/18 5 Notice of Application with SEPA comment period and hearing date 1/11/19 6 Public Meeting Sign, Mailing List, Affidavit of Publication, and Certificate of Posting Affidavit: 1/11/19, Certificate: 1/17/19 7 Notice of Mitigated Determination of Nonsignificance (MDNS) 3/22/19 8 Planning Commission Recorded Motion 4/11/19 9 Drawing Set Excerpts 11/21/18 10 Applicant Power Point Presentation Admitted 04/25/19 11 Planner Power Point Presentation Admitted 04/25/19 12 Memo to Planner from Peter Corelis, COBI Development Engineer (dated 04/24/19) Admitted 04/25/19 13 Design Review Board Minutes 12/17/2018 Admitted 04/25/19 14 Detailed Landscape Plan Admitted 04/25/19 15 EXHIBIT LIST Name App: Bainbridge High School Building 100 Replacement PLN# 51159 CUP SPR Staff Contact: David Greetham, Public Hearing: 4/25/19 Senior Planner City Hall – Council Chambers City of Bainbridge Island Hearing Examiner NO. DOCUMENT DESCRIPTION DATE A Staff Report 4/18/19 B Application 11/21/18 C Environmental (SEPA) Checklist 11/16/18 D Notice of Complete Application 12/19/18 E Notice of Application with SEPA comment period and hearing date 1/11/19 F Public Meeting Sign, Mailing List, Affidavit of Publication, and Certificate of Posting Affidavit: 1/11/19, Certificate: 1/17/19 G Notice of Mitigated Determination of Nonsignificance (MDNS) 3/22/19 H Planning Commission Recorded Motion 4/11/19 I Drawing Set Excerpts 11/21/18 J K L M N O P Q R S T U V W X ATTACHMENT A BHS Building 100 Replacement – PLN51159 SPR/CUP Page 1 of 18 Prepared by David Greetham, Senior City Planner April 18, 2019 Request: Site Plan and Design Review (SPR), PLN51159 SPR Conditional Use Permit (CUP), PLN51159 CUP Owner: Bainbridge School District Location: Bainbridge High School, 9330 NE High School Road, Bainbridge Island Tax Parcel: 222502-4-032-2008 Part I: Description of Proposal and Recommendation 1. Description of Proposal: Demolish and replace existing Building 100 on the Bainbridge High School Campus. Site work includes demolition of an existing 41,509 sq. ft. classroom and assembly building and a 2,803 sq. ft. music building, and construction of a new 35,500 sq. ft. classroom building. A building height of 30 feet is proposed, utilizing the five-foot height bonus that may be allowed for nonresidential uses under a Conditional Use Permit. The proposed site work, including new building footprint, will occur in a 2.5-acre work area within the westerly interior of the existing high school campus. The project is part of a phased plan to replace deficient school district buildings and lies immediately north of Building 200 which was replaced in the mid-2000s. The proposal does not increase student capacity and is not anticipated to result in increased average daily traffic trips. The Site Plan and Design Review and Conditional Use Permit are being reviewed under “consolidated project review” in accordance with BIMC 2.16.170. Minor (primarily interior) renovations to extant campus buildings to accommodate programs displaced by the Building 100 demolition are being reviewed under separate Tenant Improvement permits. 2. Environmental Review: In accordance with WAC 197-11-355, the Optional DNS SEPA process was utilized. A Mitigated Determination of Nonsignificance was issued on March 22, 2019. No SEPA comments or appeals were received. 3. Staff Recommendation: APPROVAL, with conditions. BHS Building 100 Replacement – PLN51159 SPR/CUP Page 2 of 18 Figure 1 – Project Limits and Site Plan BHS Building 100 Replacement – PLN51159 SPR/CUP Page 3 of 18 Part II: General Information and Site Characteristics Basic Information Zoning District R-2.9 Gross Site Area 2.5-acre work area within the 73.75-acre Bainbridge School District multi- use campus Soils and Terrain Developed site underlain by Glacial Till. The site is generally flat with moderate slopes toward access and parking areas to the north and west. Critical Areas N/A Shoreline Designation N/A Existing Development Developed high school campus in SW area of overall 73.75-acre lot Public Services and Utilities Police City of Bainbridge Island Police Department Fire Bainbridge Island Fire District Schools Bainbridge Island School District Water COBI Water Service Area Sewer COBI Sewer Service Area Storm Drainage Tying into existing drainage system with planned upgrades for water quality treatment BHS Building 100 Replacement – PLN51159 SPR/CUP Page 4 of 18 Figure 2 – Vicinity Map, Surrounding Zoning and Project Site Vicinity Map Building 100 BHS Building 100 Replacement – PLN51159 SPR/CUP Page 5 of 18 Part III: Application Background Date Action Summary June 18, 2019 Design Review Board (DRB) 1st Meeting Preliminary conceptual review and discussion. DRB received high-level overview and asked general questions about the project. June 19, 2018 Preapplication Meeting Permit process determined, including Conditional Use Permit and Site Plan and Design Review for replacement building. Determined to be exempt from development moratorium as educational facility. July 30, 2018 Preapplication Letter Sent Summary of permit process and fees August 20, 2018 DRB 2nd Meeting Detailed design review and discussion. DRB made comments relative to applicable design guidelines and requested information regarding proposal to relocate existing veteran’s memorial adjacent to building. September 24, 2018 Public Participation Meeting Meeting was lightly attended with six attendees (not including School District staff/Board members). Questions centered around new building design and plans for relocation of certain activities to extant campus buildings (e.g. future theater use in Building 200). November 5, 2018 DRB 3rd Meeting Reviewed final building design; requested landscape plan to mitigate visual effect of east building wall. Indicated likely approval following receipt of landscape plan and update on veteran’s memorial relocation. November 21, 2018 Application submitted Master Land Use Application and associated fees submitted for concurrent SPR/CUP review December 17, 2018 DRB 4th Meeting Approved Site Plan with two comments December 19, 2018 Determination of Completeness Application deemed complete April 11, 2019 Planning Commission Meeting Public meeting to review project April 25, 2019 Public Hearing Public Hearing – Hearing Examiner Review Part IV: Comprehensive Plan Goals and Policies Elements Goals and Policies Background/ Findings The Comprehensive Plan designation for the school campus is Semi-Urban -2.9. The implementing zoning regulations allow for educational facilities as a conditional use. Staff finds that the proposed redevelopment is in compliance with applicable Comprehensive Plan policies, including the key policies summarized in this section. Background: In addition to its own capital facilities planning, the City coordinates with special districts (e.g. parks, fire and schools) to ensure they are using the same BHS Building 100 Replacement – PLN51159 SPR/CUP Page 6 of 18 Capitol Facilities Element land use designations and population forecasts for their capital facilities plans. The City’s Comprehensive Plan adopts each special district Capital Facilities Plan by reference, including the Bainbridge Island School District 2014-2020 Capital Facilities Plan (October 2014). Chapter 5 (Facility Assessment) of the District Plan identifies the BHS 100 Building as one of four buildings to receive poor ratings in a 2014 evaluation of each school facility based on state standards. The report found that the existing 49-year old building does not comply with current building codes, and basic infrastructure requires significant repairs or needs to be replaced. It was also determined that the deficient facilities do not support many current educational program needs (e.g. electrical systems to support educational technology, etc.). The 2014 plan identified the likelihood of a capitol bond proposal to rectify key facility needs, which did occur and subsequently resulted in School Board approval to proceed with design and permitting of the Building 100 replacement. Policy CF 1.5 (COBI Plan): Give priority consideration to projects that: • Are required to comply with State or Federal law. • Implement the Comprehensive Plan. • Are needed to meet concurrency requirements for growth management. • Are already initiated and to be completed in subsequent phases. • Renovate existing facilities to remove deficiencies or allow their full use, and preserve the community’s prior investment or reduce maintenance and operating costs. • Replace worn-out or obsolete facilities. • Are substantially funded through grants or other outside funding. • Address public hazards. Environmental Element Policy EN-4.1: Employ conservation design methods and principles such as low impact development techniques for managing storm and waste water, green building materials, high-efficiency heating and lighting systems. Utilities Element Policy U 12.2: Within public sewer system service areas, new construction should provide for eventual connection to public sewer systems. Storm and Surface Water – Goal U-13: Manage stormwater runoff to protect life, property and habitat from flooding and erosion; to channel runoff to minimize impacts to daily activities; to protect the quality of groundwater, surface water, and the waters of Puget Sound; and to provide recharge of groundwater where appropriate. Policy U 13.2: Require new development to provide both on-site and off-site improvements necessary to avoid adverse water quality and quantity impacts. Policy U 13.5: Minimize disruption and/or degradation of natural drainage systems, minimize impervious areas by restricting site coverage, and encourage site permeability by retaining natural vegetation and buffers, and specifying use of permeable materials. Policy U 14.8: Encourage new development to integrate environmentally responsible and innovative energy systems. BHS Building 100 Replacement – PLN51159 SPR/CUP Page 7 of 18 Part V: Public Notice, Public Comments, and Agency Comments 1. Public Notice Date Action Summary January 11, 2019 Notice of Application/SEPA Comment Period/Hearing Published 30-Day Comment Period No Comments Received March 22, 2019 SEPA Determination issued (MDNS) 14-Day Appeal Period No Appeals Received 2. Public Comments Summary of Comment City Response No comments received NA 3. Agency Comments Date Agency Summary of Comment June 5, 2018 Kitsap Public Health District (KPHD) KPHD had no comments on proposed project June 20, 2018 Bainbridge Fire Department Comments and conditions provided via the pre-application process. December 17, 2018 Design Review Board (DRB) The Board recommended approval with two comments: • DRB is in agreement with locating the (veteran’s) memorial at one of two proposed locations, near the east wall of Bldg. 100 or at the end of the walk near the stadium. Both are acceptable locations. • DRB appreciates the added landscaping and trees to help break up the east wall of Bldg. 100. While this is acceptable and part of the site plan approval, DRB would encourage the applicant to consider exploring building textures to further articulate the wall and make it more interesting. February 20, 2019 COBI Building Official Conditions provided regarding compliance with building code and procedures for demolition of existing building. On-going via building review COBI Public Works - Engineering Conditions regarding stormwater management for new and replaced hard surfaces. April 11, 2019 Planning Commission Recommendation of approval by unanimous vote. Part VI: Land Use Code Analysis 1. BIMC Title 18 Zoning a. BIMC 18.09 Use Regulations Proposed Use Use Standards Educational Facility Conditional Use in the R-2.9 district BHS Building 100 Replacement – PLN51159 SPR/CUP Page 8 of 18 b. BIMC 18.12 Dimensional Standards Dimensional Standards Required/Allowed Proposed Lot Coverage 25% (73.75-acre parcel = 803,137 sq. ft. total allowed across entire lot). Existing lot coverage is estimated at approximately 12%, in compliance with the allowable coverage. Approximate 9000 sq. ft. reduction. Following demolition of approximately 44,300 sq. ft., the redeveloped building will cover approximately 35,500 sq. ft. Front Yard Setback 25 feet Exceeds setback; separated from High School Road by existing 200 Building Rear Setback 15 feet Exceeds setback; separated from rear line by existing athletic stadium. Side Yard Setbacks 5 foot minimum, 15-foot total Exceeds setbacks: 315 feet from west line; separated from east line by existing 400/500 buildings. Building Height 25 feet maximum, plus five foot- bonus for nonresidential uses if conditional use permit (CUP) conditions are met. The CUP criteria don’t contain height-specific regulations but do address compatibility with surrounding uses. 30 feet, utilizing allowable five- foot bonus for nonresidential uses at BIMC Table 18.12.020-2. Staff is recommending approval of height bonus as CUP criteria are met. c. BIMC 18.15 Development Standards and Guidelines i. BIMC 18.15.010 – Landscaping, Screening, Tree Retention, Protection and Replacement Landscape Requirements Required/Allowed Proposed Tree Units 40 tree units per acre, or at least the same number of tree units after the proposed redevelopment as it had before the redevelopment. The project area occurs in a heavily developed interior portion of the school campus, with a limited number of trees in the landscaped areas adjacent to the existing 100 Building. The landscape plan retains existing trees where feasible, removes six non-landmark trees, and adds 12 new trees, including along the east building facade in response to DRB comments. New landscape planting beds are planned in multiple areas around the building, replacing existing grass in some areas. Native vegetation will be installed in the two planned stormwater biofiltration facilities. The project is conditioned such BHS Building 100 Replacement – PLN51159 SPR/CUP Page 9 of 18 that it will have at least the same number of tree units after redevelopment as it had prior to redevelopment. Perimeter Buffer 20’ partial screen No change – proposed work area is in campus interior and separated from existing perimeter buffer by school access and parking areas to west, and other campus facilities on north, east and south. The existing forested perimeter buffer on the westerly property line varies in width from approximately 25 feet to 100 feet. Roadside Buffer 25’ partial screen/15’ minimum No change – proposed work area is in campus interior and separated from road(s) by existing campus buildings. ii. BIMC 18.15.020 – Parking and Loading Parking Requirements Required/Allowed Proposed On-Street Parking Disabled Access Parking N/A – no increase in student capacity proposed N/A Off-Street Parking N/A – no increase in student capacity proposed. (1 space per 10 students and 1 space per employee required for new projects.) Redevelop and stripe existing parking areas immediately north of 100 Building; no net change in parking proposed due to no change in student capacity. iii. BIMC 18.15.030 – Mobility and Access iv. BIMC 18.15.040 – Outdoor Lighting v. BIMC 18.15.050 – Signs Mobility Requirements Required/Allowed Proposed Bicycle Spaces N/A – no increase in student capacity proposed. (1 space per 5 parking spots, a minimum of 4 spaces per parking lot required for new projects.) Retain existing facilities – no change in student capacity. Lighting Requirements Required/Allowed Proposed Outdoor Lighting Compliance with outdoor lighting standards at BIMC 18.15.040. Outdoor lighting to be installed in compliance with code. Sign Requirements Required/Allowed Proposed BHS Building 100 Replacement – PLN51159 SPR/CUP Page 10 of 18 d. BIMC 18.18 Design Standards and Guidelines Design Guidelines Requirements Commercial and Mixed- Use Projects The Design Review Board reviewed applicable Design Guideline Checklists and recommended approval with two comments (see Agency Comments above) Business/Industrial (formerly Light Manufacturing) Part VII: Decision Criteria 1. BIMC 2.16.040 Site Plan and Design Review The director and planning commission shall base their respective recommendations or decisions on site plan and design review applications on the following criteria: Decision Criteria City Analysis and Findings 1. The site plan and design is in conformance with applicable code provisions and development standards of the applicable zoning district, unless a standard has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.S; As conditioned, the site plan and design is in conformance with the Bainbridge Island Municipal Code (BIMC) and standards of the R- 2.9 zoning district. 2. The locations of the buildings and structures, open spaces, landscaping, pedestrian, bicycle and vehicular circulation systems are adequate, safe, efficient and in conformance with the Island-Wide Transportation Plan; As conditioned, the location of the building, open spaces, landscaping, pedestrian, bicycle and vehicular circulation systems are adequate, safe, efficient and in conformance with the Island- Wide Transportation Plan. The proposal includes redevelopment within a 2.5-acre portion of the overall 73.5-acre school district parcel. The replacement building will be in the same location as the existing building, but slightly smaller in size with no proposed increase in student population. Existing perimeter landscaping, pedestrian, bicycle and vehicular circulation systems will remain in place. 3. The Kitsap County health district has determined that the site plan and design meets the following decision criteria: a. The proposal conforms to current standards regarding domestic water supply and sewage disposal. The school campus is currently served by City sewer and water. The Kitsap Public Health District reviewed and had no comments on the proposal. 4. The city engineer has determined that the site plan and design meets the following decision criteria: a. The site plan and design conforms to regulations concerning drainage in As conditioned, the City engineer has determined that the site plan and design meets the decision criteria. The applicant proposes to tie into the existing drainage system and comply with the 2014 Ecology Stormwater Manual minimum Signs NA – building is in campus interior No signs proposed BHS Building 100 Replacement – PLN51159 SPR/CUP Page 11 of 18 Chapters 15.20 and 15.21 BIMC; and b. The site plan and design will not cause an undue burden on the drainage basin or water quality and will not unreasonably interfere with the use and enjoyment of properties downstream; and c. The streets and pedestrian ways as proposed align with and are otherwise coordinated with streets serving adjacent properties; and d. The streets and pedestrian ways as proposed are adequate to accommodate anticipated traffic; and e. If the site will rely on public water or sewer services, there is capacity in the water or sewer system (as applicable) to serve the site, and the applicable service(s) can be made available at the site; and f. The site plan and design conforms to the “City of Bainbridge Island Design and Construction Standards,” unless the city engineer has approved a variation to the road standards in that document based on his or her determination that the variation meets the purposes of BIMC Title 18. requirements for new and replaced hard surfaces, and land disturbance areas. The current street and pedestrian circulation system for the High School campus will remain unchanged with the exception of new walkways around the replacement building. No new traffic trips are planned; no new impacts to existing streets and pedestrian ways are anticipated. The property is currently served by City sewer and water and the and the replacement structure is not anticipated to result in an increase in student population or service demand. The proposal conforms to the “City of Bainbridge Island Design and Construction Standards”; the City Engineer has not required road improvements due to no change in traffic trips. 5. The site plan and design is consistent with all applicable design guidelines in BIMC Title 18, unless strict adherence to a guideline has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.S; The Design Review Board reviewed the applicable Design Guideline Checklists (Commercial and Mixed-Use and Business/Industrial) and recommended approval with two comments, including a nonmandatory suggestion for the applicant’s consideration during final design of the building exterior. 6. No harmful or unhealthful conditions are likely to result from the proposed site plan; As conditioned, no harmful or unhealthful conditions are likely to result from the proposed development. 7. The site plan and design is in conformance with the Bainbridge Island Comprehensive Plan and other applicable adopted community plans; As conditioned, the proposed development is in conformance with the Bainbridge Island Comprehensive Plan. No local community plans have been adopted for the High School campus. 8. Any property subject to site plan and design review that contains a critical area or buffer, as defined in Chapter 16.20 BIMC, conforms to all requirements of that chapter; The proposed work area doesn’t contain any critical areas or buffers. 9. Any property subject to site plan and design review that is within shoreline jurisdiction, as defined in Chapter 16.12 BIMC, conforms to all requirements of that chapter; The property is not within shoreline jurisdiction. 10. If the applicant is providing privately owned No privately owned open space is proposed. BHS Building 100 Replacement – PLN51159 SPR/CUP Page 12 of 18 open space and is requesting credit against dedications for park and recreation facilities required by BIMC 17.20.020.C, the requirements of BIMC 17.20.020.D have been met; 11. The site plan and design has been prepared consistent with the purpose of the site design review process and open space goals. The site plan and design has been prepared consistent with the purpose of the site design review process and has received a recommendation of approval from the Design Review Board. An overall reduction in lot coverage is proposed. Redevelopment includes new landscape planting beds and vegetated stormwater biofiltration facilities. 2. BIMC 2.16.110 Major Conditional Use Permit A conditional use may be approved with conditions if (includes additional criteria #s 11-17 for institutional uses in residential zones): Decision Criteria City Analysis and Findings 1. The conditional use is harmonious and compatible in design, character and appearance with the intended character and quality of development in the vicinity of the subject property and with the physical characteristics of the subject property; provided, that in the case of a housing design demonstration project any differences in design, character or appearance that are in furtherance of the purpose and decision criteria of BIMC 2.16.020.Q shall not result in denial of a conditional use permit for the project; Building 100 occurs within the existing school campus. The proposed redevelopment is part of a phased upgrade of deficient and outdated school district buildings, and is harmonious and compatible in design, character and appearance with the intended character of the school campus. The proposed building lies immediately north of the 200 building, which was similarly redeveloped via a Conditional Use Permit in the mid-2000s. A single architectural firm was retained for both projects, providing for coordinated design of redevelopment activities. 2. The conditional use will be served by adequate public facilities including roads, water, fire protection, sewage disposal facilities and storm drainage facilities; The proposed redevelopment will continue to utilize existing public facilities including roads, fire protection City water and sewer, and storm drainage facilities in compliance with Department of Ecology Stormwater Manual standards. 3. The conditional use will not be materially detrimental to uses or property in the vicinity of the subject property. The conditional use is a continuation of the existing site use as an educational facility, and as conditioned is not anticipated to be materially detrimental to uses or property in the vicinity of the subject property. The current use is not expanding, and all perimeter buffers between the school site and the Commodore Lane development to the west will be retained. Demolition of the existing building is BHS Building 100 Replacement – PLN51159 SPR/CUP Page 13 of 18 conditioned for management of dust and any hazardous materials that may be encountered. Noise, lighting and tree retention standards will continue to apply to the redeveloped site. 4. The conditional use is in accord with the comprehensive plan and other applicable adopted community plans, including the Island- Wide Transportation Plan; The conditional use is in accord with the Comprehensive Plan, including the Capital Facilities element which adopts the School District Capital Facilities Plan (CFP) by reference. The School District CFP identified the existing 100 Building as one of four deficient and substandard buildings in a 2014 survey of school district facilities. The proposed redevelopment does not increase student capacity, thus will continue to rely on the existing transportation circulation system with no planned upgrades. 5. The conditional use complies with all other provisions of the BIMC, unless a provision has been modified as a housing design demonstration project pursuant to BIMC 2.16.020.Q; As conditioned, the conditional use complies with all other provisions of the BIMC. 6. All necessary measures have been taken to eliminate or reduce to the greatest extent possible the impacts that the proposed use may have on the immediate vicinity of the subject property; In addition to retention of all existing perimeter buffer vegetation between the high school campus and the adjacent Commodore Lane development to the west, demolition of the existing building is conditioned for management of dust and any hazardous materials that may be encountered. Noise, lighting and tree retention standards will continue to apply to the redeveloped site. 7. Noise levels shall be in compliance with BIMC 16.16.020 and 16.16.040.A; The proposal is conditioned for compliance with BIMC noise standards. 8. The vehicular, pedestrian, and bicycle circulation meets all applicable city standards, unless the city engineer has modified the requirements of BIMC 18.15.020.B.4 and B.5, allows alternate driveway and parking area surfaces, and confirmed that those surfaces meet city requirements for handling surface water and pollutants in accordance with Chapters 15.20 and 15.21 BIMC; The city engineer has determined that the vehicular, pedestrian, and bicycle circulation meets all applicable city standards and will not require upgrades as an increase in student capacity is not proposed. 9. The city engineer has determined that the conditional use meets the following decision criteria: i. The conditional use conforms to regulations concerning drainage in Chapters 15.20 and 15.21 BIMC; ii. The conditional use will not cause an undue burden on the drainage basin or water quality and will not unreasonably interfere with the use and enjoyment of properties downstream; The city engineer has determined that the conditional use meets the applicable decision criteria. Site redevelopment activities, including new and disturbed hard surfaces, will comply with the Stormwater Manual. The existing drainage system will be utilized upon completion of the replacement building. Existing streets and pedestrian ways have been deemed adequate as increases in student BHS Building 100 Replacement – PLN51159 SPR/CUP Page 14 of 18 iii. The streets and pedestrian ways as proposed align with and are otherwise coordinated with streets serving adjacent properties; iv. The streets and pedestrian ways as proposed are adequate to accommodate anticipated traffic; v. If the conditional use will rely on public water or sewer services, there is capacity in the water or sewer system (as applicable) to serve the conditional use, and the applicable service(s) can be made available at the site; vi. The conditional use conforms to the “City of Bainbridge Island Engineering Design and Development Standards Manual,” unless the city engineer has approved a variation to the road standards in that document based on his or her determination that the variation meets the purposes of BIMC Title 17. capacity or average daily traffic trips are not anticipated to occur as a result of the building replacement. The replacement building will continue to rely on city water and sewer service as provided to the current 100 building. The conditional use conforms to the “City of Bainbridge Island Engineering Design and Development Manual” in that no road upgrades are required for the replacement building. 10. If a major conditional use is processed as a housing design demonstration project pursuant to BIMC 2.16.020.Q, the above criteria will be considered in conjunction with the purpose, goals, policies, and decision criteria of BIMC 2.16.020.Q. Not applicable to educational facilities. 11. All sites must front on roads classified as residential suburban, collector, or arterial on the Bainbridge Island functional road classification map. The High School campus fronts on High School Road which is classified as a secondary arterial. The redevelopment occurs within the interior of the campus, and does not change or expand the pre-existing use. 12. If the traffic study shows an impact on the level of service, those impacts have been mitigated as required by the city engineer. As no increase in student capacity is proposed, a traffic study was not required by the City Engineer. 13. If the application is located outside of Winslow study area, the project shall provide vegetated perimeter buffers in compliance with BIMC 18.15.010. The current perimeter buffer located west of the work site meets minimum standards, with a forested strip ranging from approximately 25’ - 100’ in width. The proposed work area occurs within the interior of the campus and is separated from the perimeter buffer by access and parking areas. 14. The proposal meets the requirements of the commercial/mixed use design guidelines in BIMC 18.18.030.C. The proposal has been reviewed and recommended for approval by the DRB, including compliance with the commercial/mixed use design guidelines. 15. The scale of proposed construction including bulk and height and architectural design features is compatible with the immediately surrounding area. Building 100 occurs within a cluster of four relatively large campus buildings. The School District has retained the architectural firm that designed the 200 Building redevelopment BHS Building 100 Replacement – PLN51159 SPR/CUP Page 15 of 18 immediately to the south. Similar to the existing building to be demolished, the replacement building is designed to be compatible with the bulk and height of other buildings in the cluster, while still retaining design features necessary for the intended use. 16. If the facility will have attendees and employees numbering fewer than 50 or an assembly seating area of less than 50, the director may waive any or all the above requirements in this subsection E, but may not waive those required elsewhere in the BIMC. Not applicable - attendees and employees will exceed 50. 17. Lot coverage does not exceed 50 percent of the allowable lot coverage in the zone in which the institution is located, except that public schools and governmental facilities, as defined in BIMC Title 18, that are located in the R-0.4 zoning district shall be allowed 150 percent of the lot coverage established in the R-0.4 zoning district, and such public schools and governmental facilities located in other zoning districts shall be allowed 100 percent of the lot coverage established in the underlying zoning district in which the facility is located, unless, regardless of which zoning district such a facility is located, conditions are required to limit the lot coverage to mitigate impacts of the use. The school campus exists on a single 73.75-acre multi-purpose parcel. Existing overall lot coverage is estimated at approximately 12 percent, less than the allowable 25 percent for public schools in the R-2.9 zone. No special conditions are required to limit the lot coverage to mitigate use impacts. The use is existing, and the proposed redevelopment activity will result in a net reduction in lot coverage of approximately 9000 sq. ft. Part VIII: Attachments 1. Site Plans 2. SEPA Checklist 3. Applicant summary Conditional Use Permit and Site Plan Review 4. Design Guideline Checklists 5. Planning Commission Minutes April 2019 [Placeholder] Part IX: Conclusions 1. The Conditional Use Permit and Site Plan and Design Review applications are properly before the Hearing Examiner as a consolidated project review in accordance with BIMC 2.16.170. 2. The applications have been noticed in accordance with noticing procedures in the BIMC. 3. The proposal is consistent with the Bainbridge Island Comprehensive Plan, including the Capital Facilities element which adopts the Bainbridge Island School District 2014-2020 Capital Facilities Plan by reference. 4. The proposal meets the applicable Conditional Use Permit and Site Plan and Design Review criteria, including the allowable five-foot height bonus at BIMC Table 18.12.020-2. Part X: Recommendation and Conditions of Approval Staff recommends approval in accordance with the following conditions: BHS Building 100 Replacement – PLN51159 SPR/CUP Page 16 of 18 SEPA Conditions: 1. The limits of clearing and grading shall be clearly marked in the field and inspected by the Department of Planning and Community Development staff prior to start of any clearing, grading, or other site work. 2. Dust shall be managed in compliance with WAC 173-400 and Puget Sound Clean Air Agency – Regulation I, 9.15 (PSCCA Reg). The project proponent or contractor shall prepare and implement a “Dust Control Plan” in conformance with Department of Ecology Publication 96- 433. Prior to any site activity, the “Dust Control Plan” shall be submitted to the City and it shall be actively managed for the duration of the project. Unlawful emissions (see below) shall be corrected immediately and/or dust generating operations ceased until additional or alternate BMPs can be implemented to maintain emissions below allowable levels. "Fugitive dust" means a particulate (especially soil/dirt) emission made airborne by forces of nature, man's activity, or both, that leaves the subject site. Unlawful emissions shall generally be defined as emissions leaving the subject property that are visible to an untrained observer. Where continuous monitoring equipment is used particulate matter concentrations shall be monitored for 10μm particle (PM10) size. The 24-hr average PM10 emissions shall not exceed a concentration equivalent to the EPA Air Quality Index (AQI) of 50 (54μg/m³) and any instantaneous PM10 emissions shall not exceed a concentration equivalent to an AQI of 100 (154μg/m³). 3. Dangerous wastes from demolition activities shall be properly managed and disposed of in accordance with state and federal requirements. These include but are not limited to: a) the “Mercury-Containing Lights – Proper Disposal” law, Chapter 70.275 RCW; b) evaluation for asbestos, and if identified, removal and disposal in accordance with Puget Sound Clean Air Agency Regulations; and c) evaluation for lead concentrations to determine if they exceed dangerous thresholds. If lead-bearing components designate as hazardous waste, all related debris must be managed appropriately and cannot be disposed of as municipal trash. Project Conditions: General 4. Except for modifications reflecting compliance with these conditions of approval, the project shall be in substantial conformance with the site and landscape plans dated November 21, 2018. 5. Prior to construction activity, the applicant shall obtain the appropriate permits from the City of Bainbridge Island, including but not limited to grading, demolition, and building permits. 6. All work shall adhere to the City’s seasonal work limitations between October 1 and April 30 of any year. During this period, no soils shall remain exposed and unworked for more than two days. From May 1 to September 30, no soils shall remain exposed and unworked for more than seven days. 7. Prior to construction, a temporary erosion and sedimentation control plan (TESCP) shall be submitted and approved by the City. Construction shall be restricted to the dates occurring between May 1 and September 30 unless a wet weather erosion control plan is submitted and approved by the City prior to construction. 8. Construction activities shall comply with the noise limitations at BIMC 16.16.020 (maximum environmental noise levels) and BIMC 16.16.025 (limitations in residential zones). BHS Building 100 Replacement – PLN51159 SPR/CUP Page 17 of 18 9. Outdoor lighting shall be installed in accordance with the outdoor lighting standards at BIMC 18.15.040. 10. A tree unit survey shall be provided prior to final building inspection to ensure that the designated project area includes at least the same number of tree units after the proposed redevelopment as it had before the redevelopment. Calculation of tree units shall be based on BIMC Table 18.15.010-5 for preserved trees, and BIMC 18.15.010.G.5.c for newly planted trees. Building 11. The project shall comply with the City of Bainbridge Island (COBI) construction codes as adopted by the BIMC, Chapter 15.04. The applicant shall consult with the Building Official to coordinate with design professionals as necessary for this project to ensure compliance with applicable standards. 12. The project shall comply with the requirements of the Department of Labor and Industries (L&I) for Electrical permits. COBI does not issue electrical permits but does monitor and coordinate electrical approvals with L&I. 13. The project shall comply with the provisions of the International Building Code for fire separation, fire protection, access and the application of fire suppression system/s as required by State Building Code/s and the City of Bainbridge Island, fire district. The applicant shall consult with the Fire District and coordinate with design professionals as necessary for this project to ensure compliance with applicable standards. 14. The project shall comply with the provisions of the International Building Code, Chapter 11 and ANSI 117.1 2009 for the application of accessibility and accessible features, including but not limited to parking, path of travel, entry and egress components and interior features and restrooms. 15. Application for all demolition is required to be submitted to the Puget Sound Clean Air Agency prior to issuance of a COBI building demolition permit. 16. All demolition shall be documented with a minimum 8.5 x 11 drawing showing the location of structures to be demolished including footprint and setbacks from all property lines and utilities as currently installed. Fire 17. The proposed project shall comply with all applicable provisions of the adopted Fire Code. 18. The proposed Fire Lane shall be a minimum 20’ width. Bollard placement along the lane shall be verified with the Fire Department prior to installation. 19. Shop classroom uses such as spray painting, woodworking operations (dust collection), hazardous materials handling, etc. shall be subject to applicable Fire Code standards. 20. The fire alarm system shall be networked to the 200 building and annunciate there. 21. The sprinkler design PSI available shall be verified with the Fire Department prior to installation. 22. The raku kiln shall be setback a minimum of 25’ from any structure. Public Works 23. With the submittal of the building permit, the applicant shall demonstrate how storm water will be handled in conformance with current BIMC 15.20 regulations. BHS Building 100 Replacement – PLN51159 SPR/CUP Page 18 of 18 24. Low impact development methods for stormwater management shall be incorporated into the site to the maximum extent feasible. 25. DOE Stormwater Manual Minimum requirements #1-5 will apply to new hard surfaces, and minimum requirements #1-9 will apply to new hard surfaces converted from vegetation areas. 26. Prior to building permit issuance, a binding commitment letter for water and sewer availability is required. Time Limits of Approval 27. The land use permits shall automatically expire and become void if the applicant fails to apply for a building permit or other necessary development permit within three years of the effective date of the permit unless the applicant has received an extension for the permit. ATTACHMENT B ATTACHMENT C ATTACHMENT D ATTACHMENT E NOTICE OF APPLICATION/SEPA COMMENT PERIOD/HEARING The City of Bainbridge Island has received a Master Land Use Permit Application for the following project. The public has the right to review contents of the official file, provide written comments, participate in any public meetings or hearings, and request a copy of the decision. This notice is posted at the project site, in City Hall kiosks, the City of Bainbridge Island website, mailed to property owners within 500 feet of any boundary of the subject property and including any property within 500 feet of any contiguous property in the applicant’s ownership and published in the Bainbridge Island Review. PROJECT DESCRIPTION: Demolish existing 41,509 sf classroom and assembly building (existing 100 Building). Demolish existing 2,803 sf music building. Construct new 35,000 sf classroom building. Improvements to 2.5 acres of site area, including building footprint. Minor renovations to extant building to accommodate programs displaced by demolition. PROJECT NAME: BHS Bld 100 Replacement CUP/SPR PROJECT NUMBER: PLN51159 CUP/SPR PERMIT TYPE: Conditional Use Permit / Site Plan Review TAX PARCEL: 22250240032008 PROJECT SITE: Building 100, Bainbridge High School Campus, 9330 NE High School Rd DATE SUBMITTED: November 21, 2018 DATE COMPLETE: December 19, 2018 DATE NOTICED: January 11, 2019 COMMENT PERIOD: January 11, 2019 – January 25, 2019 Comments must be submitted no later than 4:00pm on Friday, January 25, 2019. Public comments may be mailed, emailed or personally delivered to the City using the staff name and contact information provided on this notice. The public comment period for this application is 14 days and the City will not act on the application nor make a threshold determination until the comment period has ended. Any person may comment on the proposed application, request notice of and participate in the public hearing and request a copy of the decision. Only those persons who submit written comments pr ior to the decision or participate in the public hearing will be parties of record and only parties of record will have the right to appeal. STAFF CONTACT: David Greetham, Senior Planner pcd@bainbridgewa.gov or 206-780-3765 DATE OF HEARING: April 11, 2019 at 10:00 AM (tentative) This is a tentative date only. Please go to the City website at bainbridgewa.gov and search 'Project Hearing Schedule' to view any updates on the date/time of the hearing. Hearings are held at Bainbridge Island City Hall, Council Chambers, 280 Madison Aven ue North, Bainbridge Island. PROJECT DOCUMENTS: https://ci-bainbridgeisland-wa.smartgovcommunity.com/PermittingPublic/PermitDetailPublic /Index/5ca7d879-8253-4e26-b722-a99f013a5177?_conv=1 To review documents and environmental studies submitted with this proposal, please follow the link above or go to the City website at bainbridgewa.gov, select 'Online Permit Center' and search using the project information noted above. Files are also avail able at the Planning & Community Development Department at City Hall (M/T/F 8:00am -4:00pm and W/Th 8:00am-12:00pm). ENVIRONMENTAL REVIEW: This proposal is subject to State Environmental Policy Act (SEPA) review as provided in WAC 197-11-800. The City, acting as lead agency, expects to issue a Determination of Non-significance (DNS) threshold determination for this proposal. Utilizing the opt ional DNS process provided in WAC 197-11-355, the comment period specified in this notice may be the only opportunity to comment on the environmental impact of this proposal. The proposal may include mitigation measures under applicable codes, and the proj ect review process may incorporate or require mitigation measures regardless of whether an Environmental Impact Statement (EIS) is prepared. A copy of the subsequent threshold determination for the proposal may be obtained upon request. REGULATIONS/POLICIES: Applicable development regulations and policies to be used for project mitigation and consistency include, but may not be limited to, the City of Bainbridge Island 2016 Comprehensive Plan, the Bainbridge Island Municipal Code (BIMC) Chapter 2.16 (Land Use Review Procedures), Title 15 (Buildings and Construction), Title 16 (Environment) and Title 18 (Zoning). OTHER PERMITS: Other permits not included in this applicat ion but known at this time include Building permits. DECISION PROCESS: This type of land use application is classified as a 'Quasi-Judicial Decision by a Hearing Examiner' pursuant to BIMC 2.16.010 -1 and requires a public hearing pursuant to BIMC 2.16.020.C. Following the close of the public hearing, the Hearing Examiner will issue a written decision and a notice of the decision will be sent to those parties who comment on this notice or participate in the public hearing. Appeal provisions will be included with the notice of decision. ATTACHMENT F PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip ABELL VIRGINIA 1527 ARTHUR PL BAINBRIDGE ISLAND WA 98110-1602 ADAMS COLLEEN F PO BOX 4604 ROLLING BAY WA 98061 AESOPH JILL 1856 SAKAI VILLAGE LOOP UNIT 23-4BAINBRIDGE ISLAND WA 98110 AIR JACK N & WILLIAMSON AIR ANNE TRUSTEES PO BOX 11468 BAINBRIDGE ISLAND WA 98110 ALAILIMA CHARLES V & MARY F 1304 KINGS PL NW BAINBRIDGE ISLAND WA 98110 ALBEE MATTHEW C & SARAH E 353 WALLACE WAY NE APT 17 BAINBRIDGE ISLAND WA 98110 AMERICAN MARINE BANK PO BOX 2156 TACOMA WA 98401-2156 AMERICANWEST BANK 110 S FERRALL ST SPOKANE WA 99202-4800 ARICK MICHAEL M &1283 SHANTI LN NW UNIT 3 BAINBRIDGE ISLAND WA 98110 BAILEY ROBERT C & MARTHA L 4959 AVALON LN BAINBRIDGE ISLAND WA 98110 BAINBRIDGE ARTISIAN RESOURCE NETWORK 8890 THREE TREE LN NE BAINBRIDGE ISLAND WA 98110-5116 BAINBRIDGE CREST HOMEOWNERS 490 MADISON AVE N STE 106 BAINBRIDGE ISLAND WA 98110 BAINBRIDGE FIRST BAPTIST 8810 MADISON Ave NE BAINBRIDGE ISLAND WA 98110 BAINBRIDGE ISLAND HS ADMIN & ORDWAY ELEM 8489 MADISON AVE NE BAINBRIDGE ISLAND WA 98110-2915 BAINBRIDGE ISLAND MASONIC CENTER 1299 GROW AVE NW BAINBRIDGE ISLAND WA 98110-2708 BAINBRIDGE ISLAND METROPOLITAN PARK &7666 NE HIGH SCHOOL RD BAINBRIDGE ISLAND WA 98110-2621 BAINBRIDGE PUBLIC LIBRARY INC PO BOX 11815 BAINBRIDGE ISLAND WA 98110 BAINBRIDGE RELIABLE STOR LLC 1080 NE FOREST ROCK LANE POULSBO WA 98370 BANNISTER PETER & BAYDO RUTH 1855 SAKAI VILLAGE LOOP UNIT 39 BAINBRIDGE ISLAND WA 98110 BARFIELD LISA G 1818 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 BARTLEY JAMES R & CAROL S 1270 SHANTI LN NE BAINBRIDGE ISLAND WA 98110 BELL BRYAN D & EMILY K 1525 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 BELL LESTER R & JUDITH C 1870 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 BIHOUSE 9039 NORTH TOWN DR NE LLC 6498 NE JUSTIN CT BAINBRIDGE ISLAND WA 98110-3495 BIRD CATHERINE & TRENNON 1305 KINGS PL NW BAINBRIDGE ISLAND WA 98110 BOON JILL 1828 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 BOW TIE LLC 525 HIGH SCHOOL RD BAINBRIDGE ISLAND WA 98110 BRISTOW DAVID & CORINNE 1762 SUSAN PL NW BAINBRIDGE ISLAND WA 98110 CARRILLO JENNIFER A 1755 LEWIS PL NW BAINBRIDGE ISLAND WA 98110 CHANDLER JOAN L 1821 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 CHANG WAYNE & WU TINA 9385 NE NORTHTOWN LOOP BAINBRIDGE ISLAND WA 98110 CHRISTIAN SCIENCE OF BAIN IS PO BOX 10448 BAINBRIDGE ISLAND WA 98110 CHRISTIANSON JESSICA 1190 NAKATA PL NW BAINBRIDGE ISLAND WA 98110 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip COLE CARSON R & KWEK MEI LOAN YOLANDA 1760 SUSAN PL NW BAINBRIDGE ISLAND WA 98110 CONATY JENNY & NEIL 1181 NAKATA PL NW BAINBRIDGE ISLAND WA 98110 COOPER NANCY L 1643 JEANNETTE PL BAINBRIDGE ISLAND WA 98110 CORDARO DAVID B & CARLTON SYLVIA J 1245 GROW AVE NW BAINBRIDGE ISLAND WA 98110 CORP OF CATHOLIC ARCHBISHOP 710 9TH AVE SEATTLE WA 98104 COULTAS ALEC M PO BOX 1511 KINGSTON WA 98346 COULTAS RICHARDS LINDA 5937 ROSE LOOP NE BAINBRIDGE ISLAND WA 98110 COULTAS THOMAS A 12420 BRIGANTINE CT KINGSTON WA 98346 CREECH WILLIAM R & MARTHA A 1761 NW SUSAN PL BAINBRIDGE ISLAND WA 98110 CUNNANE BERYL 1524 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 CURINGA GABRIELLE & SELF TIMOTHY 1240 LOVELL AVE NW BAINBRIDGE ISLAND WA 98110 CYPHER MARK P & BRANDI J 1125 LOVELL AVE NW BAINBRIDGE ISLAND WA 98110-1789 DAVIS WILLIAM & ACTOR SHARON 1863 COMMODORE LN BAINBRIDGE ISLAND WA 98110 DEGROEN LOUISE PO BOX 4789 ROLLINGBAY WA 98061-0789 DENHAM EILEEN F 1294 SHANTI LN NE BAINBRIDGE ISLAND WA 98110 DENIS ROBIN L & JOHN PETER 9321 NE HELMSMAN CT BAINBRIDGE ISLAND WA 98110 DENORMANDIE ROBERT & BARBARA 9690 BUCSIT LN NE BAINBRIDGE ISLAND WA 98110 DIEHL MICHAEL L & ROGERSON JUDITH PO BOX 10218 BAINBRIDGE ISLAND WA 98110 DUDGEON DOUGLAS J & KATHY SUE 1178 GROW AVE NW BAINBRIDGE ISLAND WA 98110 DUNN CHARLES M & MOLLY S 1531 WHITED PL NW BAINBRIDGE ISLAND WA 98110 DUNN NENA MCLIN 1120 LOVELL AVE NW BAINBRIDGE ISLAND WA 98110 DWYER JOANNA 1526 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 EDWARDS CHARLES C 1875 SAKAI VILLAGE LOOP UNIT 35 BAINBRIDGE ISLAND WA 98110 ENGLE CHARLENE C 1235 SHANTI LN UNIT 10 BAINBRIDGE ISLAND WA 98110 EVANS THERESA J 482 NICHOLSON PL NW BAINBRIDGE ISLAND WA 98110-2725 FABBRI JACKLYN M & 0001876231 1263 PATMOS LN NW BAINBRIDGE ISLAND WA 98110-1741 FEENEY DANIEL J & MARY E 9414 NE TIDAL CT BAINBRIDGE ISLAND WA 98110 FINK BARBIE 8923 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3522 FIRE DIST 02 (BAINBRIDGE IS)8895 MADISON AVE N BAINBRIDGE ISLAND WA 98110-1831 FORTE GAETANO J JR & CARLA P 1226 ANANDA PL NW BAINBRIDGE ISLAND WA 98110 FOWLER AMY L & MICHAEL E 8928 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3522 FRANZ JENNIFER STOWE 1838 SAKAI VILLAGE LOOP NE UNIT 16 2BAINBRIDGE ISLAND WA 98110 FULGHAM CHRISTINE H 8961 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3522 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip GARVEY WILLIAM S & KAY E 1802 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 GEG-BAINBRIDGE LLC 5118 JENKS POINT WAY E LAKE TAPPS WA 98391 GIAMEOS NIKOLAOS 1279 PATMOS LN NW BAINBRIDGE ISLAND WA 98110 GOURLAY JACK & MILDRED TRUSTEES 1230 ANANDA PL BAINBRIDGE ISLAND WA 98110 GRANATO SAM J 515 FERNCLIFF AVE BAINBRIDGE ISLAND WA 98110 GRAVES MARK A & MICHELLE R 1293 PATMOS LN NW BAINBRIDGE ISLAND WA 98110 GRAY MICHAEL D & JULIE K 9001 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3521 GREGOIRE JOHN ALAN & JOAN MARIE TRUSTEES 1171 LARCH AVE MORAGA CA 94556 HALL BRENDA & MASON 9323 NE HELMSMAN CT BAINBRIDGE ISLAND WA 98110 HANBY WAYNE G & NANCY L 1258 NE SHANTI LN BAINBRIDGE ISLAND WA 98110 HARRIS ROBERDS SUSAN E 11407 BLUE HERON LN NE BAINBRIDGE ISLAND WA 98110 HARRISON MEDICAL CENTER 2520 CHERRY AVE BREMERTON WA 98310-4270 HAWKINS KEVIN & KYANNE 9223 BLUEFIN PL BAINBRIDGE ISLAND WA 98110 HEATER JOHN N 1222 ANANDA PL NW BAINBRIDGE ISLAND WA 98110 HEBERT JOSEPH & ELIZABETH 1861 COMMODORE LANE NW BAINBRIDGE ISLAND WA 98110 HIGH SCHOOL GROUP LLC PO BOX 10158 BAINBRIDGE ISLAND WA 98110 HJERRILD STEVEN L & KATHRYN A 1161 GROW AVE NW BAINBRIDGE ISLAND WA 98110-1787 HONIG HELAINE E 520 HORIZON VIEW PL NW BAINBRIDGE ISLAND WA 98110 HOUSER MICHAEL T & SHARI M 1852 EDNA PL NW BAINBRIDGE ISLAND WA 98110 HUNG KRISTINE 9440 NE BLUE WAVE COURT BAINBRIDGE ISLAND WA 98110 HUPPERICH DAVID P & WENDY 1862 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110 JACOBS DAN W 1847 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 JAMES DARREN M & BRENDA M 9423 CAPSTAN DR NE BAINBRIDGE ISLAND WA 98110-4624 JOHNSON SUSAN M R 1833 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 JORDAN MARK J 9182 FERNCLIFF AVE NE BAINBRIDGE ISLAND WA 98110 KAUFMAN EDMUND G II & SING K T 1853 EDNA PL NW BAINBRIDGE ISLAND WA 98110 KEILBART PETERSON JEAN 1162 GROW AVE NW BAINBRIDGE ISLAND WA 98110 KELLER STEVEN 5185 EAGLE HARBOR DR BAINBRIDGE ISLAND WA 98110 KIMMERLEIN JOHN D & JENNIFER A 9413 NE TIDAL CT BAINBRIDGE ISLAND WA 98110 KIRSCH LAUREN B 1532 WHITED PL NW BAINBRIDGE ISLAND WA 98110 KITSAP CO CONS HOUSING AUTH 2244 NW BUCKLIN HILL RD SILVERDALE WA 98383-8303 KLEINER JOHN TAGGART 8850 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3523 KNIGHT CATHERINE & WILLIAM 1851 EDNA PL NW BAINBRIDGE ISLAND WA 98110-2627 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip KNUDSEN CLINTON S & WRIGHT TERRA J 1816 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 KOLB RONALD R 1866 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 KRETZ DONALD A 1645 JEANNETT PL NW BAINBRIDGE ISLAND WA 98110-1655 LABELLE JAMES D 1412 ELIZABETH PL BAINBRIDGE ISLAND WA 98110 LAKICH NICOLE M 1223 ANANDA PL NW BAINBRIDGE ISLAND WA 98110 LANE GERALDINE A 2213 NE VICTORIAN LN APT E BAINBRIDGE ISLAND WA 98110 LEO ROBERT D 1826 SAKAI VILLAGE LOOP UNIT 12 BAINBRIDGE ISLAND WA 98110 LEWIS MICHAEL S & LAURA B 1188 NAKATA PL NW BAINBRIDGE ISLAND WA 98110 LINDBLOOM CARL R & MENDOZA ALICE C 1220 LOVELL AVE NW BAINBRIDGE ISLAND WA 98110-2718 LIVINGSTON MAXINE S 1413 ELIZABETH PL NW BAINBRIDGE ISLAND WA 98110 LOFTUS SUSAN & VOORSANGER MATTHEW 5330 TAYLOR AVE NE BAINBRIDGE ISLAND WA 98110-3190 MACKENZIE DAVID W & LINDA S 9220 NE BLUEFIN CT BAINBRIDGE ISLAND WA 98110 MADISON AVE DEVELOPMENT 4502 14TH AVE NW SEATTLE WA 98107 MADISON PROPERTY HOLDINGS LLC 63 SCOTT CT PORT LUDLOW WA 98365-9302 MADRONA ASSISTED LIVING LLC 1400 AIRPORT WAY S SEATTLE WA 98134 MAIDEN ELANA A 1820 SAKAI VILLAGE LOOP UNIT 10 1BAINBRIDGE ISLAND WA 98110 MARGUERITE FOUNDATION PO BOX 280 LAKE OSWEGO OR 97034 MARTIN DANIEL D & DETTMER THERESA M 9128 NW WILDCAT LAKE RD BREMERTON WA 98312-9502 MATT 19:14 LLC 10834 NE MANITOU PARK BLVD BAINBRIDGE ISLAND WA 98110 MCCARTY JAMES & LINDA 1856 COMMODORE LN BAINBRIDGE ISLAND WA 98110 MCINTOSH DUNCAN & XIMENA 9006 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3521 MCMAHON JEAN 1846 SAKAI VILLAGE LOOP UNIT 19 3BAINBRIDGE ISLAND WA 98110 MCNULTY SEAN & PHAM NGA MCNULTY 1647 JEANETTE PL NW BAINBRIDGE ISLAND WA 98110 MEDINA ANTHONY M 1812 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 MEYERS BRIAN 1863 SAKAI VILLAGE LOOP STE 375 BAINBRIDGE ISLAND WA 98110 MILLER MARK RANDALL 4901 WOODRIDGE CIR ANCHORAGE AK 99516 MILLERD GREGORY & JANET ROWLEY 1533 WHITED PL NW BAINBRIDGE ISLAND WA 98110 MORSE JOANNE K 9505 SPORTSMAN CLUB RD BAINBRIDGE ISLAND WA 98110 MOSAIC PROPERTIES LLC PO BOX 10846 BAINBRIDGE ISLAND WA 98110 MYERS ANDREW D & MELINDA K 1864 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110 NAKHUDA CAROL 5600 MCLEAN DR BETHESDA MD 20814 ODONNELL DELILAH TRUSTEE PO BOX 871 SEABECK WA 98380 OLIVER DANIEL J & DEBORAH A 1763 SUSAN PLACE BAINBRIDGE ISLAND WA 98110 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip OLSON JODI L & DITMORE BRIAN K 1414 ELIZABETH PL NW BAINBRIDGE ISLAND WA 98110 OREILLY DENNIS T & JOELLEN M 8888 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3522 OSTENSON JOHN W 355 HIGH SCHOOL RD NW BAINBRIDGE ISLAND WA 98110 PARKER SEAN F 1227 ANANDA PL NW UNIT 17 BAINBRIDGE ISLAND WA 98110 PAYNE RICHARD B 9418 NE TIDAL CT BAINBRIDGE ISLAND WA 98110 PELLS JENNIFER F & CLINTON K 1510 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 PETERSON DAVID R & HOFFMAN SCHUYLER 357 HIGH SCHOOL RD NW BAINBRIDGE ISLAND WA 98110 PETTIT JERRY W & MELANIE R 1231 ANANDA PL NW UNIT 18 BAINBRIDGE ISLAND WA 98110 PHILBY RICHARD A & ADRIAN DENISE 7080 RIDGE LN NE BAINBRIDGE ISLAND WA 98110 PHILLIPS JILL MARIE 1641 JEANNETTE PL NW BAINBRIDGE ISLAND WA 98110 PNW ISLAND VILLAGE LLC 1425 FOURTH AVE STE 500 SEATTLE WA 98101 PONTIERI MICHAEL L & URSULA L 1303 KINGS PLACE NW BAINBRIDGE ISLAND WA 98110 PU JUE 343 HIGH SCHOOL RD 343 BAINBRIDGE ISLAND WA 98110 PUTNAM JUDITH J 339 HIGH SCHOOL RD NW BAINBRIDGE ISLAND WA 98110 RCG BAINBRIDGE LLC 1506 NE MESFORD RD POULSBO WA 98370-8538 REGER ANNE MARIE 1865 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 REILLY CHRIS P & SUSAN J 1860 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110 Resident 1145 Madison Ave N Bainbridge Island WA 98110 Resident 1155 NAKATA PL NW BAINBRIDGE ISLAND WA 98110 Resident 1173 Madison Ave N Bainbridge Island WA 98110 Resident 1178 LOVELL AVE NW BAINBRIDGE ISLAND WA 98110 Resident 124 HIGH SCHOOL RD NE BAINBRIDGE ISLAND WA 98110 Resident 1244 Lovell Ave NW Bainbridge Island WA 98110 Resident 1261 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 1270 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 1285 Patmos Ln NW Bainbridge Island WA 98110 Resident 1299 PATMOS LN NW BAINBRIDGE ISLAND WA 98110 Resident 1302 Kings Pl NW Bainbridge Island WA 98110 Resident 1307 Kings Pl NW Bainbridge Island WA 98110 Resident 1417 Elizabeth Pl NW Bainbridge Island WA 98110 Resident 1521 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 Resident 1532 Whited Pl NW Bainbridge Island WA 98110 Resident 1534 WHITED PL NW BAINBRIDGE ISLAND WA 98110 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip Resident 1642 JEANETTE PL NW BAINBRIDGE ISLAND WA 98110 Resident 1644 JEANETTE PL NW BAINBRIDGE ISLAND WA 98110 Resident 1855 Edna Pl NW Bainbridge Island WA 98110 Resident 1875 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 Resident 200 NE HIGH SCHOOL RD BAINBRIDGE ISLAND WA 98110 Resident 208 NE HIGH SCHOOL RD BAINBRIDGE ISLAND WA 98110 Resident 235 HIGH SCHOOL RD NW BAINBRIDGE ISLAND WA 98110 Resident 253 NE HIGH SCHOOL RD BAINBRIDGE ISLAND WA 98110 Resident 341 HIGH SCHOOL RD NW Bainbridge Island WA 98110 Resident 621 High School Rd NW Bainbridge Island WA 98110 Resident 8513 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 8677 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 8800 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 8804 MADISON AVE N BAINBRIDGE ISLAND WA 98110 Resident 8835 THREE TREE LN NE BAINBRIDGE ISLAND WA 98110 Resident 8840 THREE TREE LN NE BAINBRIDGE ISLAND WA 98110 Resident 8845 North Town Dr NE Bainbridge Island WA 98110 Resident 8897 THREE TREE LN NE BAINBRIDGE ISLAND WA 98110 Resident 9039 North Town Dr NE Bainbridge Island WA 98110 Resident 9046 North Town Dr NE Bainbridge Island WA 98110 Resident 9084 North Town Dr NE Bainbridge Island WA 98110 Resident 9433 NE Blue Wave Ct Bainbridge Island WA 98110 RETIREMENT VENTURES LLC 290 MADISON AVE N STE 200 BAINBRIDGE ISLAND WA 98110 RICHARDS JULIE M 1753 LEWIS PL NW BAINBRIDGE ISLAND WA 98110 ROSEN MICHAEL S & ANA D 1415 ELIZABETH PL NW BAINBRIDGE ISLAND WA 98110-1603 ROSS GEORGE W IV & LEWIS ROSS LAURENE L 1854 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110 RUHL STEPHEN F & PAMELA D 1754 LEWIS PL NW BAINBRIDGE ISLAND WA 98110 SAKAI TOSHIO P 19206 VIKING WAY NW POULSBO WA 98370-7213 SAKHANENKO NIKITA A &500 ALOHA ST APT 209 SEATTLE WA 98109-3972 SANCHEZ HENRIETTA M 347 HIGH SCHOOL RD NW 5B BAINBRIDGE ISLAND WA 98110 SAUNDERS MALCOLM 1416 ELIZABETH PL BAINBRIDGE ISLAND WA 98110 SAUNDERS RICHARD A 1858 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110 SCANLAN PATRICK & KATHY 1837 SAKAI VILLAGE LOOP UNIT 44 1BAINBRIDGE ISLAND WA 98110 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip SCHNUG LYN L & WILLIAMS ROBIN R 1825 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 SCHUH JO ANN C L 1752 LEWIS PL NW BAINBRIDGE ISLAND WA 98110 SHARMAN ROBERT W & PAMELA A 1184 NAKATA PL NW BAINBRIDGE ISLAND WA 98110-1788 SHAW JOHN 1411 ELIZABETH PL BAINBRIDGE ISLAND WA 98110-1603 SMATLAN J A & JOANNE 2545 12TH AVE W SEATTLE WA 98119-2116 SMITH MATTHEW W & HEFFRON ELIZABETH M 1155 20TH AVE E SEATTLE WA 98112 SMITH MICHAEL D & PATRICIA A TTEES 351 HIGH SCHOOL RD NW UNIT 351 BAINBRIDGE ISLAND WA 98110 SMITH STEVEN B 1862 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 SMITH TIMOTHY WILLIAM 8710 GRAND AVE NE BAINBRIDGE ISLAND WA 98110 SNYDER ROBERT S & SALLY J 1535 WHITED PL NW BAINBRIDGE ISLAND WA 98110 STEVEN GIRARD M & ROSEMARY W 1246 SHANTI LN NE BAINBRIDGE ISLAND WA 98110 STOCK KARL A & MARTHA P TRUSTEES 1834 SAKAI VILLAGE LOOP NE UNIT15BAINBRIDGE ISLAND WA 98110 STONE JULIE 349 HIGH SCHOOL RD NW BAINBRIDGE ISLAND WA 98110 SUTORIUS STEVEN & KERRY 1824 SAKAI VILLAGE LOOP # 111 BAINBRIDGE ISLAND WA 98110 SUTTON JAMES W & KRISTI L 1865 COMMODORE LN NW BAINBRIDGE ISLAND WA 98110-2628 SWAFFIELD JULIE 1301 KINGS PL BAINBRIDGE ISLAND WA 98110 TANAKA DOUGLAS PO BOX 4607 ROLLINGBAY WA 98061 TAPPEN MARSHALL F & JOY C 1765 SUSAN PL NW BAINBRIDGE ISLAND WA 98110 TEEHAN JOAN & TIM 1864 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 TELSCHOW KENNETH & DIANE TRUSTEES 1832 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 THE CHURCH OF JESUS CHRIST 50 E NORTH TEMPLE RM 2225 SALT LAKE CITY UT 84150-0022 THE FARM BUSINESS PARK LLC 12420 BRIGANTINE CT KINGSTON WA 98346 THOMAS ROBERT E & JANET M 550 HORIZON VIEW PL NW BAINBRIDGE ISLAND WA 98110 TINDALL KRISTINA L 1861 SAKAI VILLAGE LOOP UNIT 38 BAINBRIDGE ISLAND WA 98110 TINGLEY WYNONA W 1247 SHANTI LN NE BAINBRIDGE ISLAND WA 98110 TRUAN MICHAEL A & ALICE V 1182 NAKATA AVE NW BAINBRIDGE IS WA 98110 UHLIG MICHAEL D & ALICIA D 610 HORIZON VIEW PL NW BAINBRIDGE ISLAND WA 98110 VAN EATON MARY M & KEITH A 1751 LEWIS PL NW BAINBRIDGE ISLAND WA 98110-3663 VEERARAGHAVAN KAUSHIK & CHANG NATASHA 9318 NE HELMSMAN CT BAINBRIDGE ISLAND WA 98110-4602 VILLARREAL MINERVA 1523 ARTHUR PL NW BAINBRIDGE ISLAND WA 98110 VINCENT SUSAN JEAN 9225 NE BLUEFIN CT BAINBRIDGE ISLAND WA 98110 VIRGINIA VILLA APARTMENT 545 RAINIER BLVD STE 9 ISSAQUAH WA 98027-2806 W L MACE LLC 1298 GROW AVE NW BAINBRIDGE ISLAND WA 98110-2708 PLN51159 CUP/SPR BHS Bldg 100 Replacement January 11, 2019 Owner Mailing Address Mailing City State Mailing Zip WACHTER DAVID E & OLSEN MARISSA A 8885 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3523 WAFFLE MATTHEW P 1306 KINGS PL NW BAINBRIDGE ISLAND WA 98110 WARNER SONYA A & BENNETT DAVID R 1646 JEANNETTE PL NW BAINBRIDGE ISLAND WA 98110 WATSON C THOMAS & KRISTY 1221 ANANDA PL NW BAINBRIDGE ISLAND WA 98110 WEBBER STEVE F & DANA L 1845 SAKAI VILLAGE LOOP NE UNIT 43-2BAINBRIDGE ISLAND WA 98110 WHITMAN MICHELE 1849 SAKAI VILLAGE LOOP BAINBRIDGE ISLAND WA 98110 WIELAND SANDRA 1842 SAKAI VILLAGE LOOP NE BAINBRIDGE ISLAND WA 98110 WILLMAN JAMES & EDNA 1186 NAKATA PL NW BAINBRIDGE ISLAND WA 98110-1788 WOHLFORD GAIL B & R FRANKLIN 1295 SHANTI LN NE APT 1 BAINBRIDGE ISLAND WA 98110 WOLFE JOSEPH A & NANCY B &359 HIGH SCHOOL NW UNIT A 6 BAINBRIDGE ISLAND WA 98110 YETTE GAIL L & KENNETH N TRUSTEES 650 NW HORIZON VW PL BAINBRIDGE ISLAND WA 98110-2709 YOO MIN 1854 SAKAI VILLAGE LOOP NE UNIT 22BAINBRIDGE ISLAND WA 98110 ZAJONC DONNA J & WOMELDORFF JOHN DAVID 8966 NORTH TOWN DR NE BAINBRIDGE ISLAND WA 98110-3522 ZWIRNER DION G 1177 GROW AVE NW BAINBRIDGE ISLAND WA 98110-1787 CITY OF BA.11 1\.J B R[ DGE iS I.A\NID l, cfrtsr/ Bkeprr _ _ , eerrify flhar rhe fonnovrring sfg6s\*{*^(,) irroposecJ Land Use Aaiiiorn (# af signs posied \ )! Cneaniag Fcnm.rir 6i af sigr,ns p*iuA-_j - ) Z ,-tO inq"&ltaUtta E{earimg (# af stgns posteal ) ***/' \J :\=- Cmreegp'gcA€E otr posgENG Do P (# af signs posted\_) worc posted om 1,t?-,LoLg fo.fhe foffiowimg apptricarion at the address risted beno,w:{ri*teS Fs'ojeed F{amc & Fes.@B6lt{arnqbcr =t-rs TPhfsiealFropertyAddress - Z:Z:Z5-bZ4 o o B Z ooq. PI'axAssessor.Ne:emher{s} _ Q B= o nf Z i dealare wmc{er tke pena!'ry af r&ee xeern"wry lwws af t'fue state af wwskiragtom {kait 'ke f,aregotng is eory.eet. _:llJ!L1sigrcwtwre &s,e - fusdess*iomu r*r p*ffi6 sigl mu* Toe posted r;vith 5 husfurcss olays of Notiee,of Aipprisalrioro6 sigrl muls'f he posted nlnere ittis oontirulantry and nl**ly ,lulhnc fo passersby anel nelghbors"e slgo must -be pos'rted o-verno,on<hg tloc y'atsr ,on any yratoir,&.onit properiry*." l1p mtast he iposiied haan<+o-haa"t amol perpemeria.unar to ,the access"e Sig"o must he oin thy sgh3"ect properi*y, hTOT Lll the rigtrt_ort:way"o Slgn -must re-maan f pnacc *rrtil ipuo3eat e,orntrl1eti,on"* Llp'on iprojeeit eornplc'iioira anel/'ol-iffinatr elcalsaon, the appnieamrt is rcsponsihne for rem,ovir"ng signs" compEefe tfufie 6ora@ sva6&€E' 4'8 Eaoess"s of pcst,mg 6Bae sagres as,d q-e6ee*rs dos rl 28S &Eadisoq, Avc"'r+" m.a*6rfdg; ;&d, w-A 98Ag& _pEr^n, rvlriq.| r ir)F l"t_ANillli\JG trun eOn/diVlUi,,ill.1 DfVELOpfu.lEiNT 280 nxaUsoiii AVENTUE i\trop,rr-r e Eariusnlrcr {SiAr\jD, lq/A e g8il.0_2824 /a^r\ -A^ ----\tu'a I / EK)_s / ),J o pcel @bainb,-iclgewa"gov uyliryvy. ba in ibriclgeu.ra"gorz ATTACHMENT G ATTACHMENT H ATTACHMENT I 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A ORIGINAL SHEET SIZE: 30"x42"ISSUE:PROJECT NO:DRAWN BY:CHECKED BY:ISSUE DATE:E E MARK DATE DESCRIPTIONFOR R E F E R E N C E O N L Y COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 1 1 / 2 0 / 2 0 1 8 3 : 1 1 : 2 0 P M C : \ ~ R e v i t L o c a l F i l e s \ 2 0 1 6 9 1 5 - A r c h 1 0 0 B L D G - V 1 8 _ E A r r o y o . r v t BHS BUILDING 100 REPLACEMENT 9330 NE HIGH SCHOOL RD BAINBRIDGE ISLAND, WA 98110-2699BAINBRIDGE ISLAND SCHOOL DISTRICT 2016915.00 CheckerAuthorCONDITIONAL USE PERMIT21 NOVEMBER 2018 COVER SHEET G -001 BH S B U I L D I N G 1 0 0 R E P L A C E M E N T BA I N B R I D G E I S L A N D S C H O O L D I S T R I C T 21 NOVEMBER 2018 CO N D I T I O N A L U S E P E R M I T 93 3 0 N E H I G H S C H O O L R D BA I N B R I D G E I S L A N D , W A 9 8 1 1 0 -26 9 9 2 5 0 2 4 5 2 5 1 2 5 9 260 257 2 5 2 2 5 3 2 5 4 2 5 5 2 5 6 2 5 7 2 5 8 258 259 2 5 8 2 30 230 2 40 2 40 2 4 0 250 D Y H D Y H V. S. x x x x x x G W O O D B E N C H F.P. 2 2 5 ' 259' 25 6 ' 258' 256' 2 5 0 ' 2 4 5 ' 2 3 0 ' 2 3 5 ' 2 4 0 '2 5 0 ' 255' 2 5 6 ' 257' 2 5 6 ' 2 5 5 ' 2 4 5 ' 2 5 8 ' 2 5 7 ' 2 6 1 ' 2 5 9 ' 255' 258' 2 5 5 ' 2 5 0 ' 2 4 5 ' 2 4 2 ' 2 4 3 ' 2 4 4 ' 2 3 5 ' 2 4 0 ' 2 3 8 ' 2 5 2 ' 2 5 4 ' 2 5 5 ' 256'2 5 8 ' 258' 2 5 7 ' 2 5 7 ' 2 5 7 ' 2 5 6 ' 2 5 5 ' 2 5 5 ' 2 5 0 ' 256' 2 5 6 ' 2 5 7 ' 256' 2 5 6 ' 256' 2 5 6 ' 2 6 0 ' 2 5 7 ' 2 5 8 ' 25 7' 2 5 0 ' 2 4 0 ' 237' 238' 255' 2 5 4' 2 5 3 '2 5 1 ' 256' 255' 250' 249' 2 5 8 ' 2 5 6 ' 2 4 5 ' 2 5 9 ' 2 5 3 ' 2 5 2 ' 2 3 7 ' 2 3 8 ' 2 5 1 ' 251' 2 4 5' 2 3 8 ' 2 3 5 ' 2 4 7 ' 2 4 9 ' 2 4 6 ' 2 4 8 ' 2 4 9 ' 2 4 6 ' 2 4 7 ' 2 3 0' 2 4 5 ' 2 4 5 ' 2 4 0 ' 2 5 0 ' 2 4 1' 2 4 2 ' 2 4 3 ' 2 5 0 ' 255' 2 5 0' 2 3 5 ' 2 4 5 ' 2 5 0 ' 259' 2 4 6 ' 230' 2 3 5 ' 2 3 4 ' 2 3 7 ' 2 3 2 ' 2 3 1 ' 2 3 0 ' 228' 2 2 8 ' 2 2 6 ' 2 2 7 ' 2 2 6 '2 2 7 ' 2 2 5 ' 2 3 3' x x xxxxxxx x x x x x x x x x x x x x x x x xxxxx x x x x x x x x x x x x x xxx x x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x xxxxxxxxxx x x xxxxxxxx x x x x x x x x x x x 3 0 ' N 87°50'15" W 200 BUILDING (existing) 2-STORY 69,400 SF 300 BUILDING (existing) 2-STORY 63,750 SF 100 BUILDING 1-STORY 35,790 SF LOADING STADIUM SEATING (existing) SPORTS FIELD (existing) PARKING LOT (existing) PARKING LOT (existing) NE HIGH SCHOOL ROAD EASEMENT #958529 EA S E M E N T # 8 8 1 1 1 8 0 1 8 3 FIRE LANE M. L . K . J R . L N N E PARKING LOT (existing) PARKING LOT (proposed) PARKING LOT (proposed) PARKING LOT (existing) COVERED WORK YARD 28 7 ' - 6 3 / 4 " 79 ' - 7 " EXISTING TREE PER LANDSCAPE STAIRS PER CIVIL EXISTING RAMP 2 0 ' - 0 " RETAINING WALL PER STRUCTURAL LOCKABLE GATE VEHICLE ACCESS GATE GATE BUILDING ENTRANCE EL.258 BUILDING ENTRANCE EL.251 BUILDING ENTRANCE EL.258 BUILDING ENTRANCE EL.258 KEYED BUILDING ENTRY / EXIT EL.258 TRASH ENCLOSURE KEYED ACCESS DOOR EL.258 KEYED BUILDING ENTRY/KNOX BOX EL.258 KEYED BUILDING ENTRY / EXIT EL.258 KEYED BUILDING ENTRY / EXIT EL.258 LOCKABLE GATE 81' - 11 3/4" 10 8 ' - 8 1 / 4 " 400 BUILDING (existing) 2-STORY 32,600 SF 500 BUILDING (existing) 2-STORY 32,200 SF KEYED BUILDING ENTRY / EXIT EL.258 KEYED BUILDING ENTRY / EXIT EL.258 RIGHT OF WAY PEDESTRIAN ACCESS RIGHT OF WAY VEHICLE ACCESS KEYED BUILDING ENTRY / EXIT EL.251 50' - 4" 55 ' - 0 " 159' - 10"23' - 0"89' - 4"37' - 6"10 3 ' - 8 " 29' - 6" 34 ' - 6 " 182' - 4" 28 ' - 1 0 " 11 ' - 8 " 28 ' - 0 " 62' - 3" 97' - 9" 15 ' - 1 0 " 20' - 2" EASEMENT #1025848 EA S E M E N T # 1 0 2 5 8 4 8 EA S E M E N T # 8 8 1 1 1 8 0 1 8 3 1. SITE INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO, DIMENSIONS AND LOCATIONS OF EXISTING UTILITIES, IS BASED ON THE SURVEY BY <SURVEYOR COMPANY>, DATED MONTH DAY, 201X AND IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THE ARCHITECT TAKES NO RESPONSIBILITY FOR ITS ACCURACY. 2. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES. CARE SHOULD BE TAKEN TO AVOID DAMAGE TO OR DISTURBANCE OF EXISTING UTILITIES. 3. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. 4. FINISH GRADES AROUND BUILDING SHALL BE 6” MINIMUM BELOW FINISH FLOOR ELEVATION OR BOTTOM OF EXTERIOR CLADDING MATERIALS, UNLESS OTHERWISE NOTED. 5. UNLESS OTHERWISE NOTED, DIMENSIONS ON SITE PLAN ARE TO FACE OF CURBS, EXTERIOR FACE OF BUILDING FOUNDATIONS AND GRID LINES. GENERAL SITE NOTES PROPERTY LINE EASEMENT LINE SOW LINE GENERAL SITE NOTES PLAN NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION F O R R E F E R E N C E O N L Y COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 11 / 2 0 / 2 0 1 8 3 : 1 1 : 0 6 P M C: \ ~ R e v i t L o c a l F i l e s \ 2 0 1 6 9 1 5 - A r c h 1 0 0 B L D G - V 1 8 _ E A r r o yo . r v t BHS BUILDING 100 REPLACEMENT 9330 NE HIGH SCHOOL RD BAINBRIDGE ISLAND, WA 98110-2699 BAINBRIDGE ISLAND SCHOOL DISTRICT 2016915.00 Checker Author CONDITIONAL USE PERMIT 21 NOVEMBER 2018 ARCHITECTURAL SITE PLAN A-1011" = 30'-0"A1 SITE PLAN TAX PARCEL NO. : 22502-4-003-2008 SITUATED IN: SE 1/4. SECTION 22, TOWNSHIP 25N, RANGE E2, W.M. ZONING: R-2.9 (RESIDENTIAL) LOT SIZE & LOT AREA: 73.75 ACRES (3,212,550 SF) LEGAL DESCRIPTION:THAT PORTION OF THE SOUTHEAST 1/4 OF SECTION 22, TOWNSHIP 25 NORTH, RANGE 2 EAST, W.M., LOCATED IN KITSAP COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID SECTION 22, SAID POINT ALSO BEING THE SOUTHEAST CORNER OF A CONVEYANCE TO CONSOLIDATED SCHOOL DISTRICT NO. 303, BAINBRIDGE ISLAND, RECORDED UNDER AUDITOR'S FILE NO. 406968, RECORDS OF KITSAP COUNTY, WASHINGTON, AND RUNNING THENCE ALONG THE EAST LINE OF SAID SECTION 22 N 1 DEGREE 12' 42" E 1654.47 FEET TO THE EASTERLY EXTENSION OF THE NORTH LINE OF PARCEL B OF A CONVEYANCE TO SAID SCHOOL DISTRICT RECORDED UNDER AUDITOR'S FILE NO. 833211, RECORDS OF SAID COUNTY: THENCE N 87 DEGREES 52' 08" W 1321.14 FEET TO THE NORTHWEST CORNER OF A CONVEYANCE TO SAID SCHOOL DISTRICT RECORDED UNDER AUDITOR'S FILE NO. 937020, RECORDS OF SAID COUNTY: THENCE SOUTH 1 DEGREE 12' 00" W 794.61 FEET TO THE NORTHWEST CORNER OF A CONVEYANCE TO SAID SCHOOL DISTRICT RECORDED UNDER AUDITOR'S FILE NO. 224565, RECORDS OF SAID COUNTY: THENCE N 87 DEGREES 51' 36" W 275.00 FEET TO THE NORTHWEST CORNER OF A CONVEYANCE TO SAID SCHOOL DISTRICT RECORDED UNDER AUDITOR'S FILE NO. 404529, RECORDS OF SAID COUNTY: THENCE S 1 DEGREE 12' 00" W ALONG THE WEST LINE LEVEL 01 251' -0" LEVEL 02 258' -0" 1234567891011121314151617181920 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" DUMPSTER ENCLOSURE SHOWN DASHED TOP OF HIGH PARAPET 282' -4" TOP OF MID PARAPET 275' -0" TOP OF LOW PARAPET 268' -3" SE E C 1 / A -21 3 SE E C 1 / A -21 3 SE E D 2 / A -21 3 SE E D 2 / A -21 3 LEVEL 01 251' -0" LEVEL 02 258' -0" C E F G H I K LJBADTOP OF HIGH PARAPET 282' -4" TOP OF MID PARAPET 275' -0" TOP OF LOW PARAPET 268' -3" E.5 10' - 6" 8' - 5" 14' - 7" 4' - 4 1/2" 33' - 4" 11' - 2 7/16" 34' - 9 9/16" 11' - 9 1/2" 17' - 0 1/2" 13' - 3" 13' - 3" 15' - 2 15/16" LEVEL 01 251' -0" LEVEL 02 258' -0" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TOP OF HIGH PARAPET 282' -4" TOP OF MID PARAPET 275' -0" TOP OF LOW PARAPET 268' -3" 20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0" SE E B 1 / A -21 1 SE E B 1 / A -21 1 SE E A 1 / A -21 1 SE E A 1 / A -21 1 LEVEL 01 251' -0" LEVEL 02 258' -0" CEFGHIKLJ B ADTOP OF HIGH PARAPET 282' -4" TOP OF MID PARAPET 275' -0" TOP OF LOW PARAPET 268' -3" E.5 13' - 3" 13' - 3" 17' - 0 1/2" 11' - 9 1/2" 34' - 9 9/16" 11' - 2 7/16" 33' - 4" 4' - 4 1/2" 14' - 7" 8' - 5" 10' - 6" 15' - 2 15/16" ELEVATION GENERAL NOTES 1. REFER TO WALL SECTIONS FOR EXTERIOR WALL ASSEMBLY TYPES. 2. REFER TO EXTERIOR WINDOW TYPES SHEETS FOR WINDOW SIZES, ELEVATION ABOVE FLOOR, AND GLAZING TYPE FOR EXTERIOR WINDOWS. KEYNOTES ELEVATION MATERIAL LEGEND ELEVATION SYMBOL LEGEND (CONC) 03 30 00 PRE-CAST CONCRETE PANEL FXX 08 54 00 FIBERGLASS WINDOWS SF 08 43 13 STOREFRONT WINDOWS CJ CACONTROL JOINT CONTINUOUS ANGLE, SEE DETAILS AND STRUCT DRAWINGS DIV 26 EXTERIOR LIGHTING, REFER TO ELECTRICAL DRAWINGS CW 08 44 10 CURTAINWALL WINDOWS SXX 080 91 00 EXTERIOR LOUVERS (BR-1) 04 20 00 BRICK MASONRY (MP-1) 07 42 13 METAL PANEL (SCR-1) 05 50 00 METAL SCREEN 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION F O R R E F E R E N C E O N L Y COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 11 / 2 0 / 2 0 1 8 3 : 1 7 : 0 9 P M C: \ ~ R e v i t L o c a l F i l e s \ 2 0 1 6 9 1 5 - A r c h 1 0 0 B L D G - V 1 8 _ E A r r o yo . r v t BHS BUILDING 100 REPLACEMENT 9330 NE HIGH SCHOOL RD BAINBRIDGE ISLAND, WA 98110-2699 BAINBRIDGE ISLAND SCHOOL DISTRICT 2016915.00 Checker Author CONDITIONAL USE PERMIT 21 NOVEMBER 2018 EXTERIOR ELEVATIONS - OVERALL A-201 1/16" = 1'-0"D1 NORTH ELEVATION 1/16" = 1'-0"C1 EAST ELEVATION 1/16" = 1'-0"B1 SOUTH ELEVATION 1/16" = 1'-0"A1 WEST ELEVATION From:Joseph Dunstan To:David Greetham Cc:Joseph Dunstan Subject:HIgh School Bldg 100 site plan review Date:Wednesday, January 2, 2019 5:12:06 PM Hi David, As we discussed the DRB met December 17, 2018, to address the final two issues on the site plan review for Bldg 100. The DRB did approve the site plan with two comments only. They are: 1) DRB is in agreement with locating the memorial at one of two proposed locations, near the east wall of the Bldg 100 or at the end of the walk near the stadium. Borh are acceptable locations. 2) DRB appreciates the added landscaping and trees to help break up the east wall of Bldg 100. While this is acceptable and part of the site plan approval, DRB would encourage the applicant to consider exploring building textures to further articulate the wall and make it more interesting. The applicant does not need to return to Bainbridge Island for any further review. Please let me know if this email and the written minutes from the December 17th DRB meeting are sufficient for your purposes. Thanks Joe Dunstan DRB Chair